Vertical and Rotational Stiffness of Coracoclavicular Ligament Reconstruction: A Biomechanical Study of 3 Different Techniques
- Source :
- Arthroscopy : the journal of arthroscopicrelated surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 36(5)
- Publication Year :
- 2019
-
Abstract
- To compare the biomechanical stability of 3 different coracoclavicular reconstruction techniques under rotational and vertical loading using a cadaveric model.In total, 12 cadaveric shoulders were used for testing. The native state was first tested then followed by 3 different reconstruction configurations using suture tapes and cortical buttons: coracoid loop (CL), single-bundle (SB), and double-bundle (DB). Superior displacement was measured by cycling an inferiorly directed force of 70 N to the scapula. The rotational stiffness of the scapula was determined by cycling the scapula in rotational displacement control between 15° of internal and external rotation. The rotational stiffness of the clavicle was determined by rotating the clavicle around its long axis 20° anteriorly and 30° posteriorly in rotational displacement control. All measurements were captured over 10 cycles at a rate of 200 Hz.Both the CL and SB techniques demonstrated significantly less internal scapular rotation stiffness. (intact: 19.70 ± 9.07 cNm/deg, CL: 3.70 ± 2.63 cNm/deg, SB:4.30 ± 2.66 cNm/deg, P.001) External scapular rotation stiffness was significantly decreased in all techniques (intact: 17.70 ± 4.43 cNm/deg, CL: 3.30 ± 1.37 cNm/deg, SB: 4.50 ± 1.56 cNm/deg, DB: 4.67 ± 1.99 cNm/deg, P.001). The CL and SB reconstructions were significantly less stiff with regards to posterior rotation of the clavicle (intact: 5.60 ± 1.80 cNm/deg, CL: 2.90 ± 1.10 cNm/deg, SB: 1.40 ± 0.65 cNm/deg, P.001). Anterior rotation stiffness of the clavicle was significantly lower in all of the reconstructions (intact: 6.95 ± 1.90 cNm/deg, CL: 3.08 ± 0.84 cNm/deg, SB: 3.64 ± 0.93 cNm/deg, DB: 4.48 ± 1.21 cNm/deg, P.001).None of the described techniques provided equivalent rotational stability in all planes compared with the native state. DB reconstruction presented stiffness characteristics closest to the native state under cyclic loading during internal scapular and posterior clavicular rotation.Additional procedures such as tendon grafting or acromioclavicular ligament reconstruction may be required to control rotational stability.
- Subjects :
- Male
Rotation
Coracoid
Tendons
03 medical and health sciences
0302 clinical medicine
Imaging, Three-Dimensional
Scapula
Acromioclavicular ligament
medicine
Cadaver
Humans
Orthopedics and Sports Medicine
Orthopedic Procedures
Coracoclavicular ligament
030222 orthopedics
Sutures
Angular displacement
business.industry
Stiffness
030229 sport sciences
Middle Aged
Plastic Surgery Procedures
Biomechanical Phenomena
medicine.anatomical_structure
Acromioclavicular Joint
Ligaments, Articular
Female
medicine.symptom
Cadaveric spasm
business
Joint Capsule
Biomedical engineering
Subjects
Details
- ISSN :
- 15263231
- Volume :
- 36
- Issue :
- 5
- Database :
- OpenAIRE
- Journal :
- Arthroscopy : the journal of arthroscopicrelated surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
- Accession number :
- edsair.doi.dedup.....397218be88d9d194f85a1758fb5612ac