Back to Search
Start Over
Validation of dose distribution for liver tumors treated with real-time-image gated spot-scanning proton therapy by log data based dose reconstruction
- Source :
- Journal of Radiation Research
- Publication Year :
- 2021
- Publisher :
- Oxford University Press (OUP), 2021.
-
Abstract
- In spot scanning proton therapy (SSPT), the spot position relative to the target may fluctuate through tumor motion even when gating the radiation by utilizing a fiducial marker. We have established a procedure that evaluates the delivered dose distribution by utilizing log data on tumor motion and spot information. The purpose of this study is to show the reliability of the dose distributions for liver tumors treated with real-time-image gated SSPT (RGPT). In the evaluation procedure, the delivered spot information and the marker position are synchronized on the basis of log data on the timing of the spot irradiation and fluoroscopic X-ray irradiation. Then a treatment planning system reconstructs the delivered dose distribution. Dose distributions accumulated for all fractions were reconstructed for eight liver cases. The log data were acquired in all 168 fractions for all eight cases. The evaluation was performed for the values of maximum dose, minimum dose, D99, and D5–D95 for the clinical target volumes (CTVs) and mean liver dose (MLD) scaled by the prescribed dose. These dosimetric parameters were statistically compared between the planned dose distribution and the reconstructed dose distribution. The mean difference of the maximum dose was 1.3% (95% confidence interval [CI]: 0.6%—2.1%). Regarding the minimum dose, the mean difference was 0.1% (95% CI: −0.5%—0.7%). The mean differences of D99, D5–D95 and MLD were below 1%. The reliability of dose distributions for liver tumors treated with RGPT-SSPT was shown by the evaluation of the accumulated dose distributions.
- Subjects :
- Health, Toxicology and Mutagenesis
Dose distribution
dose reconstruction
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
motion management
Planned Dose
Log data
proton therapy
Humans
Medicine
Radiology, Nuclear Medicine and imaging
Fundamental Radiation Science
Radiation treatment planning
Proton therapy
Spot scanning
Radiation
business.industry
Liver Neoplasms
Reproducibility of Results
Dose-Response Relationship, Radiation
Radiotherapy Dosage
Confidence interval
spot scanning
030220 oncology & carcinogenesis
log data
AcademicSubjects/SCI00960
AcademicSubjects/MED00870
Tomography, X-Ray Computed
Fiducial marker
Nuclear medicine
business
Subjects
Details
- ISSN :
- 13499157 and 04493060
- Volume :
- 62
- Database :
- OpenAIRE
- Journal :
- Journal of Radiation Research
- Accession number :
- edsair.doi.dedup.....3b5640b58140232faf4e3560d86e0660
- Full Text :
- https://doi.org/10.1093/jrr/rrab024