Back to Search Start Over

Improvement of Stand-Alone Solar PV Systems in the Maputo Region by Adapting Necessary Parameters

Authors :
Shyama P. Chowdhury
Paxis Marques João Roque
Zhongjie Huan
Source :
Energies; Volume 14; Issue 14; Pages: 4357, Energies, Vol 14, Iss 4357, p 4357 (2021)
Publication Year :
2021
Publisher :
Multidisciplinary Digital Publishing Institute, 2021.

Abstract

With the energy crisis and the constant blackout in the Mozambique Power Company grid, the option of applying solar photovoltaic (PV) systems has been one of the most used alternatives in the neighborhoods of the Maputo region. However, inefficient power delivery caused by unproper sizing and installation of stand-alone solar PV systems has been contributing to the low utilization of solar energy potential in the Maputo region. The optimal sizing and installation of the solar PV system is addressed to evaluate the influence of installation and operation parameters on the power output of PV modules. In this topic, PV modules parameters such as cell temperature, the module’s slope and azimuth angles, the losses caused by excessive heating of the module cells, shadows and dust on the PV module and the cooling process at the back of the module are assessed in order to find out the consequence of inadequate installation and operation parameters of solar PV systems in the Maputo region. The proper sizing and installation of the stand-alone solar PV system is fundamental to guarantee the continuous and efficient supply of power and, thus, different tools and techniques have been applied. This study will deal with the hybrid optimization of multiple energy resources (HOMER) and system advisor model (SAM), to size and improve power generation of solar PV systems. This study concluded that for the Maputo region, the optimal tilt angle is 23 ± 2° and the azimuth angle is 11 ± 2°. In addition, for optimization of the tilt and azimuth angles, it also examined the effect of module backside ventilation and proved that the system’s power generation increases with the rise of spacing between the module and the wall, since the strategy prevents the decline of the module cells efficiency. However, the maximum recommended spacing between the PV module and the mounting wall is about 0.4 m, since an effort to increase the spacing up to this level results in an insignificant growth of power output.

Details

Language :
English
ISSN :
19961073
Database :
OpenAIRE
Journal :
Energies; Volume 14; Issue 14; Pages: 4357
Accession number :
edsair.doi.dedup.....3b83b2c766f063f85c1259e844f7887d
Full Text :
https://doi.org/10.3390/en14144357