Back to Search Start Over

Direct electrochemical determination of Candida albicans activity

Authors :
Rabeay Y. A. Hassan
Ursula Bilitewski
Helmholtz Centre for Infection Research, Working Group BiSA, Inhoffenstr. 7, 38124 Braunschweig, Germany
Microanalysis Lab, Applied Organic Chemistry Department, National Research Centre (NRC), Eltahrir Street, 12311-Dokki, Cairo, Egypt. Electronic address: rabeayy@yhaoo.com.
Source :
Biosensors and Bioelectronics. 49:192-198
Publication Year :
2013
Publisher :
Elsevier BV, 2013.

Abstract

Despite advances made in the field, rapid detection methods for the human pathogen Candida albicans are still missing. In this regard, bio-electrochemical systems including electrochemical sensors and biosensors satisfy the increasing demand for rapid, reliable, and direct microbial analyses. In this study, the bioelectrochemical characteristics of C. albicans were investigated for use in an analytical system that determines the viability of the organisms. The electrochemical responses of viable and non-viable cells of C. albicans and Saccharomyces cerevisiae were monitored. Cyclic voltammograms (CV) showed an irreversible oxidation peak at about 750 mV that accounts for viable cells. The peak current increased at viable cell numbers ranging from 3 × 10(5) to 1.6 × 10(7)cells/ml, indicating that the amount of viable cells can be accurately quantified. To elucidate the underlying electron transfer processes, the influence of electron transfer chain (ETC) - inhibitors on the electrochemical behavior of the two organisms were investigated. Inhibition of the function of classical respiratory chain (CRC) led to a decrease in the electrochemical response, whereas the oxidation current increased when the alternative oxidase (AOX) pathway was blocked by salicylhydroxamic acid (SHA). Blocking the AOX pathway improved the electrochemical performance, suggesting an involvement in the CRC, with cytochrome c oxidase (COX) as a relevant protein complex. Mutants, in which components of COX were deleted, showed a lower electro-activity than the wild-type strain. Particularly, deletion of subunit COX5a almost completely abolished the electrochemical signal. We believe that this work can be utilized for the development of early detection assays and opens the door for new technological developments in the field of C. albicans.

Details

ISSN :
09565663
Volume :
49
Database :
OpenAIRE
Journal :
Biosensors and Bioelectronics
Accession number :
edsair.doi.dedup.....3d01217e525eade3f943f4695a1d3564
Full Text :
https://doi.org/10.1016/j.bios.2013.05.015