Back to Search
Start Over
Lead-Acid Battery Sizing for a DC Auxiliary System in a Substation by the Optimization Method
- Source :
- Energies, Vol 12, Iss 22, p 4400 (2019), Energies, Volume 12, Issue 22
- Publication Year :
- 2019
- Publisher :
- MDPI AG, 2019.
-
Abstract
- Lead-acid batteries are the most frequently used energy storage facilities for the provision of a backup supply of DC auxiliary systems in substations and power plants due to their long service life and high reliability. It is possible to define the load in these systems, therefore the IEEE 485 Standard can be used for the selection of batteries according to the conventional method of selection. Special attention is paid in the paper to the technical selection of a lead-acid battery, which depends on its operational reliability that decreases with battery aging. It is defined by the extent of maintenance during its service life. A cost analysis was also carried out, which took into consideration maintenance and procurement costs, as well as the costs of the related air conditioning that keeps the prescribed temperature and ventilates the battery room. The impact is shown of selecting a lead-acid battery on the battery room&rsquo<br />s operating safety when charging. The final selection of lead-acid battery is performed using an optimization algorithm of differential evolution. Using the optimization process, the new battery selection method includes the technical sizing criteria of the lead-acid battery, reliability of operation with maintenance, operational safety, and cost analysis. Two cases of selection of lead-acid batteries for the backup supply of a DC auxiliary system in a transmission substation are presented in the paper, where the input data were determined based on measurements in an existing substation. A comparison is made between the existing conventional and new lead-acid battery selection method based on optimization.
- Subjects :
- Battery (electricity)
Control and Optimization
Computer science
020209 energy
Energy Engineering and Power Technology
02 engineering and technology
lcsh:Technology
Energy storage
law.invention
Battery room
Reliability (semiconductor)
dc auxiliary system
law
0202 electrical engineering, electronic engineering, information engineering
Electrical and Electronic Engineering
Lead–acid battery
Engineering (miscellaneous)
Selection (genetic algorithm)
substation
Renewable Energy, Sustainability and the Environment
lead-acid battery
lcsh:T
020208 electrical & electronic engineering
Sizing
Reliability engineering
Transmission (mechanics)
optimization methods
Energy (miscellaneous)
Subjects
Details
- Language :
- English
- ISSN :
- 19961073
- Volume :
- 12
- Issue :
- 22
- Database :
- OpenAIRE
- Journal :
- Energies
- Accession number :
- edsair.doi.dedup.....3dff66621b05f5c6eccf2a096c525e1b