Back to Search
Start Over
Chitosan-based biomaterials used in critical-size bone defects: radiographic study in rat's calvaria
- Source :
- Revista de Odontologia da UNESP v.41 n.5 2012, Revista de Odontologia da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP, Revista de Odontologia da UNESP, Vol 41, Iss 5, Pp 312-317, SciELO, Repositório Institucional da UNESP
- Publication Year :
- 2012
- Publisher :
- Universidade Estadual Paulista Júlio de Mesquita Filho, 2012.
-
Abstract
- Made available in DSpace on 2021-07-14T10:50:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-10. Added 1 bitstream(s) on 2021-07-14T11:39:25Z : No. of bitstreams: 1 S1807-25772012000500003.pdf: 973486 bytes, checksum: 9d5b5eb4b720266200309ed6d51b7833 (MD5) OBJETIVO: Este estudo avaliou através de imagens radiográficas digitais, a ação de biomateriais de quitosana e de cloridrato de quitosana, com baixo e alto peso molecular, utilizados na correção de defeitos ósseos de tamanho crítico (DOTC)em calvária de ratos. MATERIAL E MÉTODO: DOTCs com 8 mm de diâmetro foram criados cirurgicamente na calvária de 50 ratos Holtzman. Em 10 animais o defeito foi preenchido foram preenchidos com coágulo sanguíneo (controle negativo). Os 40 animais restantes foram divididos de acordo com o biomaterial utilizado no preenchimento do defeito (quitosana de baixo peso e de alto peso molecular, e cloridrato de quitosana de baixo e de alto peso molecular), e foram avaliados em dois períodos experimentais (15 e 60 dias), totalizando 5 animais/biomaterial/período de avaliação. RESULTADO: A avaliação radiográfica foi feita utilizando duas radiografias digitais do crânio do animal: uma tomada logo após o defeito ósseo ser criado e a outra no momento do sacrifício. Nessas imagens, foi avaliada a densidade óssea radiográfica inicial e a final na área do defeito, que foram comparadas. As análises na densidade óssea radiográfica indicaram aumento da densidade óssea radiográfica dos DOTCs tratados para todos os biomateriais testados, em ambos os períodos. Resultados semelhantes foram encontrados no grupo controle. CONCLUSÃO: Conclui-se que os biomateriais de quitosana testados não foram capazes de aumentar a densidade radiográfica em DOTC realizados em calvária de ratos. OBJECTIVE: This study evaluated, using digital radiographic images, the action of chitosan and chitosan hydrochloride biomaterials, with both low and high molecular weight, used in the correction of critical-size bone defects (CSBD's) in rat's calvaria. MATERIAL AND METHOD: CSBD's with 8 mm in diameter were surgically created in the calvaria of 50 Holtzman rats and these were filled with a blood clot (Control), low molecular weight chitosan, high molecular weight chitosan, low molecular weight chitosan hydrochloride and high molecular weight chitosan hydrochloride, for a total of 10 animals, which were divided into two experimental periods (15 and 60 days), for each biomaterial. The radiographic evaluation was made using two digital radiographs of the animal's skull: one taken right after the bone defect was created and the other at the moment of the sacrifice, providing the initial and the final radiographic bone density in the area of the defect, which were compared. RESULT: Analysis of radiographic bone density indicated that the increase in the radiographic bone density of the CSBD's treated with the proposed biomaterials, in either molecular weight, in both observed periods, where similar to those found in control group. CONCLUSION: Tested chitosan-based biomaterials were not able to enhance the radiographic density in the CSBD's made in rat's calvaria. Aarhus University, Department of Dentistry São Paulo State University, Araraquara Dental School University of São Paulo, São Carlos Chemistry Institute São Paulo State University, Araraquara Dental School
- Subjects :
- Bone density
regeneração óssea
biocompatible materials
lcsh:Medicine
Dentistry
Calvaria
chitin
interpretação de imagem radiográfica assistida por computador
Chitosan
chemistry.chemical_compound
radiographic image interpretation computer-assisted
quitina
bone regeneration
medicine
Biocompatible materials
quitosana
Bone regeneration
Chemistry
business.industry
lcsh:R
Biomaterial
General Medicine
Bone defect
lcsh:RK1-715
Skull
medicine.anatomical_structure
lcsh:Dentistry
Materiais biocompatíveis
Chitosan hydrochloride
chitosan
business
Biomedical engineering
Subjects
Details
- Language :
- English
- ISSN :
- 18072577
- Database :
- OpenAIRE
- Journal :
- Revista de Odontologia da UNESP v.41 n.5 2012, Revista de Odontologia da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP, Revista de Odontologia da UNESP, Vol 41, Iss 5, Pp 312-317, SciELO, Repositório Institucional da UNESP
- Accession number :
- edsair.doi.dedup.....3e550388dcee44036ec2374cb4055c11