Back to Search
Start Over
Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride
- Source :
- ChemistryOpen, RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia, instname
- Publication Year :
- 2012
- Publisher :
- WILEY-VCH Verlag, 2012.
-
Abstract
- [EN] The synthesis of capped mesoporous silica nanoparticles (MSN) conjugated with an antibody (AB) as a gatekeeper has been carried out in order to obtain a delivery system able to release an entrapped cargo (dye) in the presence of a target molecule (antigen) to which the conjugated antibody binds selectively. In particular, MSN loaded with rhodamine B and functionalized on the external surface with a suitable derivative of N-(t-butyl)- 3-oxo-(5a,17b)-4-aza-androst-1-ene-17-carboxamide (finasteride) have been prepared (S1). The addition of polyclonal antibodies against finasteride induced capping of the pores due to the interaction with the anchored hapten-like finasteride derivative to give a MSN¿hapten¿AB nanoparticle S1-AB. It was found that the addition of capped material S1-AB to water solutions containing finasteride resulted in displacement of the antibody, pore uncapping and entrapped-dye release. The response of the gated material is highly selective, and only finasteride, among other steroids, was able to induce a significant uncapping process. Compared with finasteride, the finasteride metabolite was able to release 17% of the dye, whereas the exogen steroids testosterone, metenolone and 16-b-hydroxystanozolol only induced very little release of rhodamine B (lower than 10%) from aqueous suspensions containing sensing solid S1-AB. A detection limit as low as 20 ppb was found for the fluorimetric detection of finasteride. In order to evaluate a possible application of the material for label-free detection of finasteride, the capped material was isolated and stored to give final sensing solid S1-AB-i. It was found to display a similar behavior towards finasteride as to that shown by freshly prepared S1-AB; even after a period of two months, no significant loss of selectivity or sensitivity was noted. Moreover, to study the application for the detection of finasteride in biological samples, this ¿aged¿ material, S1-AB-i, was tested using commercially available blank urine as matrix. Samples containing 70 and 90% blank urine were spiked with a defined amount of finasteride, and the concentration was determined using capped S1-AB-i. Recovery ranges from 94% to 118% were reached.<br />Financial support from the Spanish Government (project MAT2009-14564-C04-01) and the Generalitat Valenciana (Spain) (projects PROMETEO/2009/016 and PROMETEO/2010/008) is gratefully acknowledged. E. C. thanks the Minesterio de Ciencia e Innovacion (MICINN, Spain) for her fellowship.
- Subjects :
- Detection limit
INGENIERIA DE LA CONSTRUCCION
Aqueous solution
Chromatography
QUIMICA INORGANICA
Nanotechnology
General Chemistry
Mesoporous silica
Full Papers
MCM-41
finasteride
Matrix (chemical analysis)
chemistry.chemical_compound
QUIMICA ORGANICA
chemistry
QUIMICA ANALITICA
hybrid materials
Finasteride
Rhodamine B
antibodies
Selectivity
Mesoporous material
molecular gates
Subjects
Details
- Language :
- English
- ISSN :
- 21911363
- Volume :
- 1
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- ChemistryOpen
- Accession number :
- edsair.doi.dedup.....3f9906c1535fb8ad8bc02385947e2200