Back to Search
Start Over
Effect of linewidth on estimation of metabolic concentration when using water lineshape spectral model fitting for single voxel proton spectroscopy at 7 T
- Source :
- Journal of Magnetic Resonance, 304, pp. 53-61, Journal of Magnetic Resonance, 304, 53-61, Journal of magnetic resonance, 304, 53-61. Academic Press Inc.
- Publication Year :
- 2019
-
Abstract
- Good B0 field homogeneity is considered an essential requirement to obtain high-quality MRS data. Many commonly used spectral fitting methods assume that all metabolite signals have Lorentzian or Gaussian shapes. However, B0 inhomogeneity can both broaden the linewidth and modify the lineshape. In this study, it is hypothesized that a realistic metabolite fitting model, which accounts for B0 homogeneity on the basis of the water lineshape, will improve the accuracy of estimation of metabolite concentrations. In-vivo water suppressed/unsuppressed single voxel spectroscopy signals were acquired under three different B0 field homogeneity regimes. Individual realistic basis sets were created for each acquisition. Frequency-domain spectral fitting with LCModel was used to quantify the metabolite concentrations with fitting uncertainties given in terms of the Cramer-Rao lower bound. The quantification results obtained using the water lineshape basis set yielded similar concentrations independent of linewidth and showed a larger fitting error as the linewidth increased. The conventional approach, however quantifies metabolite concentrations with greater variations despite showing a supposedly improved fitting quality. The water lineshape basis set achieved single voxel spectroscopy accuracy that is less sensitive to the linewidth compared to the conventional spectral fitting method for the range of linewidths used in this study, but the precision deteriorated with worsening B0 field inhomogeneity. The beneficial effect was ascribed to a reduction in the number of degrees of freedom when using the water lineshape to generate the basis set.
- Subjects :
- Adult
Male
Nuclear and High Energy Physics
Magnetic Resonance Spectroscopy
Materials science
Single voxel
Gaussian
Medizin
Biophysics
UT-Hybrid-D
Signal-To-Noise Ratio
Water lineshape fitting model
Biochemistry
Upper and lower bounds
150 000 MR Techniques in Brain Function
Laser linewidth
symbols.namesake
Imaging, Three-Dimensional
All institutes and research themes of the Radboud University Medical Center
130 000 Cognitive Neurology & Memory
Homogeneity (physics)
Urological cancers Radboud Institute for Molecular Life Sciences [Radboudumc 15]
Humans
Single-voxel spectroscopy
Spectroscopy
Basis set
Brain
Water
B field inhomogeneity
Condensed Matter Physics
22/4 OA procedure
Computational physics
Ultrahigh field
Single voxel spectroscopy
symbols
Female
Protons
Fitting freedom
Algorithms
Subjects
Details
- Language :
- English
- ISSN :
- 10907807
- Volume :
- 304
- Database :
- OpenAIRE
- Journal :
- Journal of magnetic resonance
- Accession number :
- edsair.doi.dedup.....40079bbb8509364716462bdd592d2488
- Full Text :
- https://doi.org/10.1016/j.jmr.2019.05.002