Back to Search Start Over

Portable laboratory platform with electrochemical biosensors for immunodiagnostic of hepatitis C virus

Authors :
João Paulo de Campos da Costa
Paulo Inácio da Costa
W.B. Bastos
João Paulo Carmo
Maria Aparecida Zaghete
Elson Longo
Universidade de São Paulo (USP)
Universidade Federal de São Carlos (UFSCar)
Universidade Estadual Paulista (Unesp)
Source :
Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual), Universidade de São Paulo (USP), instacron:USP, Scopus, Repositório Institucional da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP
Publication Year :
2019

Abstract

Made available in DSpace on 2020-12-12T01:42:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-11-15 This paper presents a portable laboratory platform (PLP) with electrochemical amperometric biosensors for the detection of hepatitis C virus (HCV). This PLP is composed by a controller unit, a Bluetooth module to provide communication with mobile devices, and a potentiostat circuit to perform cyclic voltammetry. The Bluetooth communication allows the mobile devices to set up the parameters, e.g., a cycling voltage in the range ±1.5 V, a scan rate in the range 5-1000 mV-1 with a step potential of 2.318 mV, and up to 4000 number of scan cycles. The electrochemical sensors were functionalized with cystamine (C4H12N2S2) and glutaraldehyde (C5H8O2) to make the covalent binding with the recombinant core-HCV protein. The experimental results have revealed a positive detection of HCV, using a redox solution of 5 mmol.L-1 of potassium ferrocyanide (K3 Fe(CN)6) on 0.1 mol.L-1 of phosphate-buffered saline (PBS). The sensitivity of the immunosensor was established at the concentration of 1 ng. μ L-1 of the anti-core-HCV IgG class antibody. This PLP has a plug-and-play connection for the biosensors, and at the same time, it offers good ergonomy with easy operation due to its low dimensions (115 mm × 75 mm × 30 mm). This PLP presents a power consumption of 280.5 mW when supplied with a 3.3-V voltage source. This consumption was measured in the worst operation case, e.g., with the Bluetooth working, resulting in an average battery life of 195 min. Department of Electrical Engineering (SEL) University of São Paulo (USP) Department of Chemistry INCTMN-CDMF Federal University of São Carlos (UFSCar) Department of Clinical Analysis School of Pharmaceutical Sciences Laboratory of Clinical Immunology and Molecular Biology (LICBM) São Paulo State University (UNESP) Institute of Chemistry São Paulo State University (UNESP) Department of Clinical Analysis School of Pharmaceutical Sciences Laboratory of Clinical Immunology and Molecular Biology (LICBM) São Paulo State University (UNESP) Institute of Chemistry São Paulo State University (UNESP)

Details

Database :
OpenAIRE
Journal :
Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual), Universidade de São Paulo (USP), instacron:USP, Scopus, Repositório Institucional da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP
Accession number :
edsair.doi.dedup.....419156beb88844ab7b3061e5306b51ad