Back to Search Start Over

Mesenchymal stem/stromal cell quality control: validation of mixed lymphocyte reaction assay using flow cytometry according to ICH Q2(R1)

Authors :
Loïc Reppel
Lionel Faivre
Tess Nicotra
Thomas Belmas
Justine Halimi
Floriane Stranieri
Alice Freton
Audrey Cras
Miryam Mebarki
Aurélie Desnos
Jérôme Larghero
Hélène Antonot
Ingénierie Moléculaire et Physiopathologie Articulaire (IMoPA)
Université de Lorraine (UL)-Centre National de la Recherche Scientifique (CNRS)
Source :
Stem Cell Research and Therapy, Stem Cell Research and Therapy, BioMed Central, 2020, 11 (1), ⟨10.1186/s13287-020-01947-6⟩, Stem Cell Research & Therapy, Vol 11, Iss 1, Pp 1-10 (2020), Stem Cell Research & Therapy
Publication Year :
2020
Publisher :
HAL CCSD, 2020.

Abstract

Background Mesenchymal stem/stromal cells (MSC) have immunomodulatory properties, studied in a wide range of diseases. Validated quality controls must confirm this activity in the context of clinical trials. This study presents a method’s validation, assessing MSC’s ability to inhibit lymphocyte proliferation, according to the ICH Q2 standard. Methods MSC were co-cultured with CellTrace™ Violet-labeled Peripheral blood mononuclear cells (PBMC) coming from a bank of ten donors, at seven different ratios for 7 days. Cell trace violet PBMC bank was validated in parallel. Flow cytometry analysis was used to obtain the division percentage of T cells. The percentage of inhibition of lymphocyte proliferation by MSC, for each ratio X, was calculated using the formula: Ratio × percentage of inhibition = (control percentage of division—ratio × percentage of division)/control percentage of division. The inhibition percentage of lymphocyte proliferation function of co-culture ratios was represented in a line graph. The corresponding area under the curve was calculated, representing MSC’s ability to inhibit lymphocyte proliferation. Results Two cell trace violet PBMC banks were compared for bank validation. When compared using four different MSC samples coming each from a different donor, their area under the curve did not show any statistical differences and were correlated. Moreover, the stability of one cell trace violet PBMC bank was confirmed up to 509 days of storage. Analytical parameters were investigated for method validation. Analysis of repeatability and reproducibility respectively showed a standard deviation of 6.1% and 4.6%. The assay was robust regarding PBMC, as no statistical differences were found between inhibitory activities when testing three adjacent concentrations of PBMC. Still, attention is needed on MSC quantity as it can influence results. Linearity was evaluated: the percentage of inhibition of lymphocyte proliferation function of co-culture ratios was linear on the exploited range. Finally, the assay measurement range allowed to differentiate MSC presenting different inhibition activities. Conclusion This quantification method displayed low analytical variability and no inter-bank variability of PBMC. However, MSC quantification should be checked before co-culture to reduce variability. Therefore, it could be used for the qualification of MSC batches’ immunomodulatory activity.

Details

Language :
English
ISSN :
17576512
Database :
OpenAIRE
Journal :
Stem Cell Research and Therapy, Stem Cell Research and Therapy, BioMed Central, 2020, 11 (1), ⟨10.1186/s13287-020-01947-6⟩, Stem Cell Research & Therapy, Vol 11, Iss 1, Pp 1-10 (2020), Stem Cell Research & Therapy
Accession number :
edsair.doi.dedup.....42a8966f24119b7e6b033d55547a7867