Intersession Repeatability of Structural Biomarkers in Early and Intermediate Age-Related Macular Degeneration: A MACUSTAR Study Report

Authors :
Marlene, Saßmannshausen
Sarah, Thiele
Charlotte, Behning
Maximilian, Pfau
Matthias, Schmid
Sérgio, Leal
Ulrich F O, Luhmann
Robert P, Finger
Frank G, Holz
Steffen, Schmitz-Valckenberg
Source :
Translational Vision Science & Technology
Publication Year :
2022
Publisher :
Association for Research in Vision and Ophthalmology (ARVO), 2022.

Abstract

To analyze the intersession repeatability of structural biomarkers in eyes with early and intermediate age-related macular degeneration (iAMD) within the cross-sectional part of the observational multicenter MACUSTAR study.Certified site personnel obtained multimodal imaging data at two visits (38 ± 20 [mean ± standard deviation] days apart), including spectral-domain optical coherence tomography (SD-OCT). One junior reader performed systematic and blinded grading at the central reading center, followed by senior reader review. Structural biomarkers included maximum drusen size classification (63 to ≤125 µm vs.125 µm), presence of large pigment epithelium detachments (PEDs), reticular pseudodrusen (RPD), vitelliform lesions, and refractile deposits. Intrasession variability was assessed using Cohen's κ statistics.At the first visit, 202 study eyes of 202 participants were graded as manifesting with either early (n = 34) or intermediate (n = 168) AMD. Grading of imaging data between visits revealed perfect agreement for the maximum drusen size classification (κ = 0.817; 95% confidence interval, 0.70-0.94). In iAMD eyes, perfect to substantial agreement was determined for the presence of large PEDs (0.87; 0.69-1.00) and RPD (0.752; 0.63-0.87), while intersession agreement was lower for the presence of vitelliform lesions (0.649; 0.39-0.65) and refractile deposits (0.342; -0.029-0.713), respectively.Multimodal retinal imaging analysis between sessions showed a higher repeatability for structural biomarkers with predefined cutoff values than purely qualitative defined parameters.A high repeatability of retinal imaging biomarkers will be important to implement automatic grading approaches and to establish robust and meaningful structural clinical endpoints for future interventional clinical trials in patients with iAMD.

Details

ISSN :
21642591
Volume :
11
Database :
OpenAIRE
Journal :
Translational Vision Science & Technology
Accession number :
edsair.doi.dedup.....42e5a657b07ed3fd66ae010518627f94
Full Text :
https://doi.org/10.1167/tvst.11.3.27