Back to Search
Start Over
Implantable cardiac pacemaker failure by cumulative dose effects of flattening filter free beams
- Source :
- Journal of Radiation Research
- Publication Year :
- 2021
- Publisher :
- Oxford University Press, 2021.
-
Abstract
- Cumulative dose effects, which are one of the main causes of errors that occur when an implantable cardiac pacemaker (ICP) is irradiated with ionizing radiation, induce permanent failure in ICPs. Although flattening filter free (FFF) beams, which are often used in stereotactic radiotherapy, are known to have different characteristics from conventional (with flattening filter [WFF]) beams, the cumulative dose effects on ICPs with FFF beams have been under-investigated. This study investigates ICP failure induced by cumulative dose effects of FFF beams. When the ICP placed in the center of the irradiation field was irradiated with 10 MV-FFF at 24 Gy/min, the cumulative dose at which failure occurred was evaluated on the basis of the failure criteria associated with high cumulative dose as described in the American Association of Physicists in Medicine Task Group 203. The ICP failures such as a mild battery depletion at a cumulative dose of 10 Gy, pacing-output voltage change >25% at a cumulative dose of 122 Gy, and the loss of telemetry capability at cumulative dose 134 Gy were induced by cumulative dose effects. The cumulative doses by which the cumulative dose effects of FFF beams induced ICP failure were not very different from those reported in previous studies with WFF beams. Therefore, radiotherapy with FFF beams (and WFF beams) for patients with ICP requires appropriate management for minimizing the cumulative dose effects.
- Subjects :
- Pacemaker, Artificial
Health, Toxicology and Mutagenesis
medicine.medical_treatment
cumulative dose effects
030218 nuclear medicine & medical imaging
Ionizing radiation
Oncology/Medicine
Stereotactic radiotherapy
03 medical and health sciences
0302 clinical medicine
medicine
Electric Impedance
Radiology, Nuclear Medicine and imaging
Irradiation
Implantable cardiac pacemaker
radiotherapy
Task group
Radiation
Flattening filter free
integumentary system
Cumulative dose
business.industry
musculoskeletal, neural, and ocular physiology
Dose-Response Relationship, Radiation
Prostheses and Implants
implantable cardiac pacemaker (ICP)
failure
Radiation therapy
030220 oncology & carcinogenesis
AcademicSubjects/SCI00960
AcademicSubjects/MED00870
Nuclear medicine
business
FFF beams
Subjects
Details
- Language :
- English
- ISSN :
- 13499157 and 04493060
- Volume :
- 62
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Journal of Radiation Research
- Accession number :