Back to Search Start Over

Comparison of Different Electrode Configurations for the oVEMP With Bone-Conducted Vibration

Authors :
Floris L. Wuyts
Leen Maes
Stefanie Krijger
Robby Vanspauwen
Source :
Ear and hearing
Publication Year :
2017
Publisher :
Ovid Technologies (Wolters Kluwer Health), 2017.

Abstract

Objectives: This study was performed to compare three electrode configurations for the ocular vestibular evoked myogenic potentials (oVEMPs)-"standard," "sternum," and "nose"-by making use of bone-conducted stimuli (at the level of Fz with a minishaker). In the second part, we compared the test-retest reliability of the standard and nose electrode configuration on the oVEMP parameters. Design: This study had a prospective design. Fourteen healthy subjects participated in the first part (4 males, 10 females; average age = 23.4 (SD = 2.6) years; age range 19.9 to 28.3 years) and second part (3 males, 11 females; average age = 22.7 (SD = 2.4) years; age range 20.0 to 28.0 years) of the study. OVEMPs were recorded making use of a hand-held bone conduction vibrator (minishaker). Tone bursts of 500 Hz (rise/fall time = 2 msec; plateau time = 2 msec; repetition rate = 5.1 Hz) were applied at a constant stimulus intensity level of 140 dB FL. Results: PART 1: The n10-p15 amplitude obtained with the standard electrode configuration (mean = 15.8 mu V; SD = 6.3 mu V) was significantly smaller than the amplitude measured with the nose (Z = -3.3; p = 0.001; mean = 35.0 mu V; SD = 19.1 mu V) and sternum (Z = -3.3; p = 0.001; mean = 27.1 mu V; SD = 12.2 mu V) electrode configuration. The p15 latency obtained with the nose electrode configuration (mean = 14.2 msec; SD = 0.54 msec) was significantly shorter than the p15 latency measured with the standard (Z = -3.08; p = 0.002) (mean = 14.9 msec; SD = 0.75 msec) and sternum (Z = -2.98; p = 0.003; mean = 15.4 msec; SD = 1.07 msec) electrode configuration. There were no differences between the n10 latencies of the three electrode configurations. The 95% prediction intervals (given by the mean +/- 1.96 * SD) for the different interocular ratio values were [-41.2; 41.2], [-37.2; 37.2], and [-25.9; 25.9] for standard, sternum, and nose electrode configurations, respectively. PART 2: Intraclass correlation (ICC) values calculated for the oVEMP parameters obtained with the standard electrode configuration showed fair to good reliability for the parameters n10-p15 amplitude (ICC = 0.51), n10 (ICC = 0.52), and p15 (ICC = 0.60) latencies. The ICC values obtained for the parameters acquired with the nose electrode configuration demonstrated a poor reliability for the n10 latency (ICC = 0.37), a fair to good reliability for the p15 latency (ICC = 0.47) and an excellent reliability for the n10-p15 amplitude (ICC = 0.85). Conclusions: This study showed the possible benefits from alternative electrode configurations for measuring bone-conducted-evoked oVEMPs in comparison with the standard electrode configuration. The nose configuration seems promising, but further research is required to justify clinical use of this placement.

Details

ISSN :
01960202
Volume :
38
Database :
OpenAIRE
Journal :
Ear & Hearing
Accession number :
edsair.doi.dedup.....443015efcb4d1c746aa1948ff3564020
Full Text :
https://doi.org/10.1097/aud.0000000000000372