Back to Search
Start Over
Proton range verification in inhomogeneous tissue: Treatment planning system vs. measurement vs. Monte Carlo simulation
- Source :
- PLoS ONE, PLoS ONE, Vol 13, Iss 3, p e0193904 (2018)
- Publication Year :
- 2018
- Publisher :
- Public Library of Science, 2018.
-
Abstract
- In particle radiotherapy, range uncertainty is an important issue that needs to be overcome. Because high-dose conformality can be achieved using a particle beam, a small uncertainty can affect tumor control or cause normal-tissue complications. From this perspective, the treatment planning system (TPS) must be accurate. However, there is a well-known inaccuracy regarding dose computation in heterogeneous media. This means that verifying the uncertainty level is one of the prerequisites for TPS commissioning. We evaluated the range accuracy of the dose computation algorithm implemented in a commercial TPS, and Monte Carlo (MC) simulation against measurement using a CT calibration phantom. A treatment plan was produced for eight different materials plugged into a phantom, and two-dimensional doses were measured using a chamber array. The measurement setup and beam delivery were simulated by MC code. For an infinite solid water phantom, the gamma passing rate between the measurement and TPS was 97.7%, and that between the measurement and MC was 96.5%. However, gamma passing rates between the measurement and TPS were 49.4% for the lung and 67.8% for bone, and between the measurement and MC were 85.6% for the lung and 100.0% for bone tissue. For adipose, breast, brain, liver, and bone mineral, the gamma passing rates computed by TPS were 91.7%, 90.6%, 81.7%, 85.6%, and 85.6%, respectively. The gamma passing rates for MC for adipose, breast, brain, liver, and bone mineral were 100.0%, 97.2%, 95.0%, 98.9%, and 97.8%, respectively. In conclusion, the described procedure successfully evaluated the allowable range uncertainty for TPS commissioning. The TPS dose calculation is inefficient in heterogeneous media with large differences in density, such as lung or bone tissue. Therefore, the limitations of TPS in heterogeneous media should be understood and applied in clinical practice.
- Subjects :
- Proton
Statistical methods
Monte Carlo method
Carbonates
Cancer Treatment
lcsh:Medicine
Bone tissue
Biochemistry
030218 nuclear medicine & medical imaging
Diagnostic Radiology
0302 clinical medicine
Neoplasms
Range (statistics)
Medicine and Health Sciences
Proton Therapy
lcsh:Science
Radiation treatment planning
Tomography
Bone mineral
Multidisciplinary
Pharmaceutics
Phantoms, Imaging
Physics
Applied Mathematics
Simulation and Modeling
Radiology and Imaging
Radiotherapy Dosage
Chemistry
medicine.anatomical_structure
Oncology
030220 oncology & carcinogenesis
Physical Sciences
Calibration
Protons
Algorithms
Research Article
Materials science
Imaging Techniques
Bone and Mineral Metabolism
Statistics (mathematics)
Neuroimaging
Imaging phantom
03 medical and health sciences
Dose Prediction Methods
Diagnostic Medicine
medicine
Humans
Radiometry
Nuclear Physics
Nucleons
Radiotherapy Planning, Computer-Assisted
lcsh:R
Chemical Compounds
Biology and Life Sciences
Antineoplastic Protocols
Computed Axial Tomography
Research and analysis methods
Metabolism
Mathematical and statistical techniques
lcsh:Q
Radiotherapy, Intensity-Modulated
Mathematics
Biomedical engineering
Neuroscience
Subjects
Details
- Language :
- English
- ISSN :
- 19326203
- Volume :
- 13
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- PLoS ONE
- Accession number :