Central Corneal Edema with Scleral-Lens Wear

Authors :
Clayton J. Radke
Bo Tan
Meng C. Lin
Young Hyun Kim
Source :
Kim, YH; Tan, B; Lin, MC; & Radke, CJ. (2018). Central Corneal Edema with Scleral-Lens Wear. Current Eye Research, 43(11), 1305-1315. doi: 10.1080/02713683.2018.1500610. UC Berkeley: Retrieved from: http://www.escholarship.org/uc/item/6k70p2nq, Current eye research, vol 43, iss 11
Publication Year :
2018
Publisher :
eScholarship, University of California, 2018.

Abstract

© 2018, © 2018 Taylor & Francis Group, LLC. Purpose: To evaluate the safety of scleral-lens designs, we model and clinically assess central corneal edema induced by scleral-lens wear for healthy subjects. Materials and Methods: Central corneal swelling during scleral-lens wear is measured using optical coherence tomography (OCT). Transport resistances are modeled for oxygen diffusion through the scleral lens and post-lens tear-film (PoLTF), and into the cornea. Oxygen deficiency in the cornea activates anaerobic metabolic reactions that induce corneal edema. Oxygen permeability, carbon-dioxide permeability, settled-lens PoLTF thickness, and scleral-lens thickness are varied in the calculations to mimic different lens fits. Results: Transport modeling predicts that for open eyes, increasing PoLTF thickness from 50 to 400 µm increases central corneal swelling by approximately 1–1.5% when oxygen transmissibility (Dk/L) is greater than 10 hBarrer/cm (i.e., hectoBarrer/cm). Although swelling is larger for oxygen Dk/L 40 hBarrer/cm. For closed eye, central corneal swelling is greater than 5% for an oxygen Dk/L range of 0–100 hBarrer/cm with typical lens-fitting parameters. For carbon-dioxide transmissibilities increasing from 50 to 250 hBarrer/cm and with a fixed oxygen Dk/L of 25 hBarrer/cm, calculated swelling diminishes by an additional 0.5%. Comparison of model calculations to clinical-swelling data is within the error range of the clinical measurements. Conclusions: Oxygen/metabolite transport calculations for open-eye scleral-lens wear show that typical PoLTF thicknesses fitted by clinicians (i.e., PoLTF thicknesses 25 hBarrer/cm) produce corneal swelling of less than 2% in agreement with experiment. Therefore, scleral lenses prescribed today evoke less than physiological hypoxic swelling (i.e., less than 4%) for healthy corneas during open-eye. Closed-eye wear, however, appears clinically unsafe.

Details

Language :
English
Database :
OpenAIRE
Journal :
Kim, YH; Tan, B; Lin, MC; & Radke, CJ. (2018). Central Corneal Edema with Scleral-Lens Wear. Current Eye Research, 43(11), 1305-1315. doi: 10.1080/02713683.2018.1500610. UC Berkeley: Retrieved from: http://www.escholarship.org/uc/item/6k70p2nq, Current eye research, vol 43, iss 11
Accession number :
edsair.doi.dedup.....44c4be3cb0f8e0e47b90e22d94ead1be