Back to Search
Start Over
Good Validity and High Internal Consistency of the Forgotten Joint Score-12 in Patients After Medial Opening Wedge High Tibial Osteotomy
- Source :
- The Journal of Arthroplasty. 36:2691-2697
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- Background The Forgotten Joint Score-12 (FJS-12) was originally developed to assess awareness of an artificial joint. Medial opening wedge high tibial osteotomy (MOWHTO), an alternative surgical method of knee replacement, is a joint-preservation surgery; therefore, joint awareness should be used to evaluate its clinical results. However, FJS-12 has not been validated as a tool to evaluate the postoperative results of MOWHTO. This study aimed to validate FJS-12 in MOWHTO. Methods Patients with bilateral knee surgery, previous knee surgery, flexion contracture >15°, varus alignment >20°, and patients without plate removal surgery were excluded. Finally, 71 knees of 71 patients were analyzed, with a mean follow-up of 34.5 months. The FJS-12 score and Knee Injury and Osteoarthritis Outcome Score (KOOS) were obtained, and the floor and ceiling effect of each score was investigated. Cronbach’s α was calculated to determine the internal consistency of FJS-12. Spearman’s correlation coefficients between FJS-12 and KOOS were calculated to assess convergent validity. Results There were ceiling effects in 3 KOOS subscales (symptoms [25.4%], pain [15.5%], and activities of daily living [25.4%]) but not in FJS-12 (8.5%). No floor effect was noted in any patient-reported outcome measures. The total Cronbach’s α was 0.9457 in FJS-12. FJS-12 showed moderate-to-strong positive correlations with all KOOS subscales (r = 0.64-0.72). Conclusion FJS-12 showed a lower ceiling effect than KOOS and high internal consistency and convergent validity in patients following MOWHTO. With its low ceiling effect, FJS-12 was found to be useful for evaluating patients following MOWHTO.
- Subjects :
- Knee Joint
medicine.medical_treatment
Knee replacement
Osteoarthritis
03 medical and health sciences
0302 clinical medicine
Cronbach's alpha
High tibial osteotomy
Floor effect
Activities of Daily Living
medicine
Humans
Orthopedics and Sports Medicine
Patient Reported Outcome Measures
Arthroplasty, Replacement, Knee
Orthodontics
Flexion contracture
030222 orthopedics
business.industry
Reproducibility of Results
Osteoarthritis, Knee
medicine.disease
Osteotomy
Convergent validity
Ceiling effect
business
Subjects
Details
- ISSN :
- 08835403
- Volume :
- 36
- Database :
- OpenAIRE
- Journal :
- The Journal of Arthroplasty
- Accession number :
- edsair.doi.dedup.....45efb5668f31f17a25a84fdde6fac774
- Full Text :
- https://doi.org/10.1016/j.arth.2021.03.028