Back to Search Start Over

Influence of agitation methods of irrigants after methylene blue-mediated PDT on the bonding interface of a fiber post cementation system

Authors :
Lucas David Galvani
Joatan Lucas de Sousa Gomes Costa
João Felipe Besegato
Joissi Ferrari Zaniboni
Wilfredo Gustavo Escalante-Otárola
Milton Carlos Kuga
Universidade Estadual Paulista (UNESP)
Source :
Scopus, Repositório Institucional da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP
Publication Year :
2022
Publisher :
Elsevier BV, 2022.

Abstract

Made available in DSpace on 2022-04-29T08:38:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2022-03-01 Background: This study evaluated the effects of final agitation methods of irrigants to remove methylene blue and sodium hypochlorite residues after PDT-assisted endodontic treatment on the bond strength of fiber posts cemented with etch-and-rinse adhesive and conventional resin cement. Methods: Ninety bovine teeth were endodontically treated. In sequence, post space preparation followed by methylene blue-mediated PDT and sodium hypochlorite (NaOCl) irrigation were performed. Six final irrigations protocols for dye and NaOCl removal were performed prior to cementation with etch-and-rinse adhesive (Adper Scocthbond Multipurpose) and conventional dual resin cement (RelyX ARC): Conventional endodontic irrigation (CEI), passive ultrasonic irrigation (PUI), mechanical agitation with XP Endo Finisher (XPF), XP Clean (XPC) or Easy Clean (ECL) and distilled water (NCO - control). After fiber post cementation, push-out bond strength test was performed at different thirds of the post space. Failure mode was also analyzed. ANOVA and Tukey's post-hoc test was used for data analysis (α=5%). Results: PUI, XPF e XPC protocols showed the highest bond strength values with no difference among them (p > 0.05), although they were similar to NCO, regardless of the post space third. CEI e ECL showed similar bond strength values, regardless of the third (p > 0.05). Adhesive failure was the most incident for CEI and ECL, while mixed and cohesive failures were predominant in PUI, XPF, XPC and NCO groups. Conclusions: Mechanical agitation of distilled water with XPF, XPC and PUI after methylene blue-mediated PDT and irrigation with 2.5% sodium hypochlorite promoted bond strength of the resin cementation system in post space dentin comparable to control group. Department of Restorative Dentistry School of Dentistry Araraquara Sao Paulo State University – UNESP, SP Department of Restorative Dentistry School of Dentistry Araraquara Sao Paulo State University – UNESP, SP

Details

ISSN :
15721000
Volume :
37
Database :
OpenAIRE
Journal :
Photodiagnosis and Photodynamic Therapy
Accession number :
edsair.doi.dedup.....468df459e033fe226c32703a658c9a4f
Full Text :
https://doi.org/10.1016/j.pdpdt.2021.102708