Low-noise readout of superconducting bolometers based on electrothermal feedback

Authors :
Panu Helistö
Jari Penttilä
Hannu Sipola
Heikki Seppä
Source :
Penttilä, J S, Sipola, H, Helistö, P & Seppä, H 2006, ' Low-noise readout of superconducting bolometers based on electrothermal feedback ', Superconductor Science and Technology, vol. 19, no. 4, pp. 319-322 . https://doi.org/10.1088/0953-2048/19/4/013
Publication Year :
2006
Publisher :
Institute of Physics IOP, 2006.

Abstract

We have developed a simple room-temperature readout for superconducting bolometers and calorimeters. Due to electro-thermal feedback, the bolometer can be noise-matched with the readout amplifier. The constructed amplifier consists of low-noise field-effect transistors, and voltage bias is actively provided by electrical feedback. According to our measurements on superconducting vacuum-bridge bolometers, the total noise is limited by the bolometer phonon and Johnson noise characterized by a critical temperature of 8.5 K. We show that, with proper sensor design, it is possible to reach the photon noise limit in video-rate submillimetre imaging applications.