A comparison of AmnioStat-FLM with three established methods of assessing fetal lung maturity

Authors :
M.J. Whittle
C.R. Whitfield
A.I. MacGillivray
P.G. O'Dwyer
Source :
European Journal of Obstetrics & Gynecology and Reproductive Biology. 27:59-63
Publication Year :
1988
Publisher :
Elsevier BV, 1988.

Abstract

Summary A new rapid test of fetal lung maturity (the AmnioStat-FLM) was compared with two currently available rapid tests and with 2-dimensional thin-layer chromatography (2-d TLC). Forty-nine specimens of liquor obtained within 72 h of delivery were assessed, 27 of which were contaminated with blood or meconium. The AmnioStat-FLM compared well with spectrophotometry, the shake test and with 2-d TLC. Only the Amniostat-FLM and the 2-d TLC were reliable in the presence of contamination. The results suggest that the AmnioStat-FLM is a reliable, rapid test and unaffected by the presence of contamination.

Details

ISSN :
03012115
Volume :
27
Database :
OpenAIRE
Journal :
European Journal of Obstetrics & Gynecology and Reproductive Biology
Accession number :
edsair.doi.dedup.....47e9765f0d43f8c7442ef758361b3426
Full Text :
https://doi.org/10.1016/s0028-2243(88)80011-x