Effect of Head Position and Tube Entry on Corneal Endothelial Cells in Patients with Glaucoma Drainage Implants: A Cross-sectional Study
- Source :
- Korean Journal of Ophthalmology : KJO
- Publication Year :
- 2020
- Publisher :
- Korean Ophthalmological Society, 2020.
-
Abstract
- Purpose To investigate the effect of head tilt on the tube position of the Ahmed glaucoma valve (AGV) implanted in patients with glaucoma and to assess how the head tilt-induced alterations of tube parameters and the level of tube entry influence corneal endothelial cell density (ECD). Methods A total of 29 eyes of 26 patients with AGV implantation were included. Tube-cornea distance, tube-cornea angle, and intracameral tube length were measured using anterior segment optical coherence tomography in three different head positions (neutral, 30° temporalward tilt, and 30° nasalward tilt). The tube entry was assessed using static gonioscopy. ECD was measured using specular microscopy before and after surgery. Results The mean tube-cornea distance, tube-cornea angle, and intracameral tube length (neutral: 0.87 ± 0.39 mm, 30.56 ± 5.89˚, and 3.10 ± 0.82 mm, respectively) decreased with head tilts (temporalward: 0.82 ± 0.39 mm, 29.27 ± 5.82˚, and 3.04 ± 0.82 mm, respectively; nasalward: 0.83 ± 0.40 mm, 29.61 ± 6.04˚, and 3.05 ± 0.81 mm, respectively; all p l 0.01). The multivariate analyses found age and the tube insertion level to be associated with postoperative changes in the central ECD (p = 0.039 and 0.013, respectively), and the postoperative follow-up period and tube insertion level to be associated with the difference between the inferonasal and superotemporal ECDs (p = 0.034 and 0.007, respectively). Conclusions Mild alterations of head positions induced changes in the intracameral tube positions of AGV implants; nevertheless, it did not significantly affect ECD loss. However, the eyes with tubes inserted anteriorly to Schwalbe's line may be more susceptible to corneal ECD loss.
- Subjects :
- medicine.medical_specialty
genetic structures
Anterior Chamber
Posture
Glaucoma
Corneal endothelial cell loss
Glaucoma valve
03 medical and health sciences
0302 clinical medicine
Ophthalmology
medicine
Gonioscopy
Humans
Tube (fluid conveyance)
In patient
Intraocular Pressure
Glaucoma drainage implant
Optical coherence tomography
medicine.diagnostic_test
business.industry
Endothelial Cells
General Medicine
medicine.disease
Cross-Sectional Studies
Tilt (optics)
030221 ophthalmology & optometry
Head position
Original Article
sense organs
Glaucoma drainage implants
business
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 20929382 and 10118942
- Volume :
- 34
- Database :
- OpenAIRE
- Journal :
- Korean Journal of Ophthalmology
- Accession number :
- edsair.doi.dedup.....47eb77fda82e2ffc918a451eb4f8748c
- Full Text :
- https://doi.org/10.3341/kjo.2020.0104