Sorry, I don't understand your search. ×
Back to Search Start Over

Late-Term Clinical Outcomes With Zotarolimus- and Sirolimus-Eluting Stents

Authors :
Mark Turco
Jeffrey J. Popma
Peter J. Fitzgerald
David E. Kandzari
Martin B. Leon
Laura Mauri
Paul A. Gurbel
Source :
JACC: Cardiovascular Interventions. 4:543-550
Publication Year :
2011
Publisher :
Elsevier BV, 2011.

Abstract

Objectives This study sought to compare late safety and efficacy outcomes following percutaneous coronary revascularization with zotarolimus-eluting stents (ZES) and sirolimus-eluting stents (SES). Background Despite higher late lumen loss and binary restenosis with ZES compared with SES, it is uncertain whether differences in early angiographic measures translate into more disparate late clinical events. Methods Clinical outcomes were prospectively evaluated through 5 years in the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) that randomized 436 patients of relatively low anatomic and clinical risk to treatment with ZES (n = 323) or SES (n = 113) and evaluated a primary endpoint of 8-month angiographic late lumen loss. Results At 5 years (completeness of follow-up: 95.2%), pre-specified endpoints of all-cause mortality (5.2% vs. 13.0%, p = 0.02), myocardial infarction (1.0% vs. 4.6%, p = 0.03), and the composite event rates of cardiac death/myocardial infarction (1.3% vs. 6.5%, p = 0.009) and major adverse cardiac events (14.0% vs. 22.2%, p = 0.05) were significantly lower among patients treated with ZES. Rates of target lesion (8.1% ZES vs. 6.5% SES, p = 0.68) and target vessel revascularization were similar between treatment groups. Stent thrombosis was infrequent and similar in both groups (0.7% ZES vs. 0.9% SES, p = 1.0). Between 9 months and 5 years, progression of major adverse cardiac events was significantly more common with SES than with ZES (16.7% vs. 7.8%, p = 0.015). Conclusions Despite initially higher angiographic late lumen loss, rates of clinical restenosis beyond the protocol-specified angiographic follow-up period remain stable with ZES compared with the rates for SES, resulting in similar late-term efficacy. Over 5 years, significant differences in death, myocardial infarction, and composite endpoints favored treatment with ZES. (The Medtronic Endeavor III Drug Eluting Coronary Stent System Clinical Trial [ENDEAVOR III]; NCT00217256 )

Details

ISSN :
19368798
Volume :
4
Database :
OpenAIRE
Journal :
JACC: Cardiovascular Interventions
Accession number :
edsair.doi.dedup.....48239ff2b85a059b4b4cf1eccbc018ad
Full Text :
https://doi.org/10.1016/j.jcin.2010.12.014