Back to Search
Start Over
The impact of ventilation–perfusion inequality in COVID-19: a computational model
- Source :
- Journal of Applied Physiology
- Publication Year :
- 2021
- Publisher :
- American Physiological Society, 2021.
-
Abstract
- COVID-19 infection may lead to acute respiratory distress syndrome (CARDS) where severe gas exchange derangements may be associated, at least in the early stages, only with minor pulmonary infiltrates. This may suggest that the shunt associated to the gasless lung parenchyma is not sufficient to explain CARDS hypoxemia. We designed an algorithm (VentriQlar), based on the same conceptual grounds described by J.B. West in 1969. We set 498 ventilation–perfusion (VA/Q) compartments and, after calculating their blood composition (PO2, PCO2, and pH), we randomly chose 106 combinations of five parameters controlling a bimodal distribution of blood flow. The solutions were accepted if the predicted PaO2 and PaCO2 were within 10% of the patient’s values. We assumed that the shunt fraction equaled the fraction of non-aerated lung tissue at the CT quantitative analysis. Five critically-ill patients later deceased were studied. The PaO2/FiO2 was 91.1 ± 18.6 mmHg and PaCO2 69.0 ± 16.1 mmHg. Cardiac output was 9.58 ± 0.99 L/min. The fraction of non-aerated tissue was 0.33 ± 0.06. The model showed that a large fraction of the blood flow was likely distributed in regions with very low VA/Q (Qmean = 0.06 ± 0.02) and a smaller fraction in regions with moderately high VA/Q. Overall LogSD, Q was 1.66 ± 0.14, suggestive of high VA/Q inequality. Our data suggest that shunt alone cannot completely account for the observed hypoxemia and a significant VA/Q inequality must be present in COVID-19. The high cardiac output and the extensive microthrombosis later found in the autopsy further support the hypothesis of a pathological perfusion of non/poorly ventilated lung tissue. NEW & NOTEWORTHY Hypothesizing that the non-aerated lung fraction as evaluated by the quantitative analysis of the lung computed tomography (CT) equals shunt (VA/Q = 0), we used a computational approach to estimate the magnitude of the ventilation–perfusion inequality in severe COVID-19. The results show that a severe hyperperfusion of poorly ventilated lung region is likely the cause of the observed hypoxemia. The extensive microthrombosis or abnormal vasodilation of the pulmonary circulation may represent the pathophysiological mechanism of such VA/Q distribution.
- Subjects :
- medicine.medical_specialty
Ventilation perfusion inequality
Coronavirus disease 2019 (COVID-19)
Physiology
medicine.medical_treatment
Computed tomography
gas exchange
Respiratory physiology
mechanical ventilation
Ventilation/perfusion ratio
03 medical and health sciences
0302 clinical medicine
ventilation-perfusion
Physiology (medical)
Internal medicine
Medicine
030212 general & internal medicine
Mechanical ventilation
lung physiology
Lung
medicine.diagnostic_test
business.industry
COVID-19
030208 emergency & critical care medicine
respiratory tract diseases
medicine.anatomical_structure
Cardiology
business
Shunt (electrical)
Research Article
Subjects
Details
- ISSN :
- 15221601 and 87507587
- Volume :
- 130
- Database :
- OpenAIRE
- Journal :
- Journal of Applied Physiology
- Accession number :
- edsair.doi.dedup.....4a20b6c36c5c6dfd103566ea3284aae2
- Full Text :
- https://doi.org/10.1152/japplphysiol.00871.2020