Back to Search Start Over

Feasibility of myocardial perfusion imaging with half the radiation dose in obese patients using ordered-subset expectation maximization with resolution recovery software

Authors :
Tamir Bental
Alejandro Solodky
Yosef Hassid
Nili Zafrir
Doron Belzer
Ariel Gutstein
Avi Ben-Shlomo
Alexander Battler
Israel Mats
Source :
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 20(1)
Publication Year :
2012

Abstract

We previously described the feasibility of myocardial perfusion imaging (MPI) with nearly half the radiation dose using ordered-subset expectation maximization with resolution recovery (OSEM-RR) processing. This study sought to determine if the findings can be expanded to obese patients. Fifty obese patients (>100 kg) referred for MPI underwent stress-rest or rest-stress studies with a half dose of Tc-99m sestamibi in a 1-day protocol using OSEM-RR processing. Image quality and clinical results were compared with matched patients (by age, sex, weight, presence/probability of coronary artery disease) evaluated with standard “full-dose” Tc-99m sestamibi, mostly in a 2-day protocol. Dose activities were adjusted individually by weight. Mean Tc-99m activity was 33.4 ± 13.9 mCi in the half-dose group and 60 ± 10 mCi in the full-dose group (P

Details

ISSN :
15326551
Volume :
20
Issue :
1
Database :
OpenAIRE
Journal :
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology
Accession number :
edsair.doi.dedup.....4ae0263beb959e589204a01d973886a7