Back to Search Start Over

De la construction du bunker à la prise en charge du patient : contrôles qualité des techniques modernes de radiothérapie

Authors :
C. Martin
Thomas Zilli
C.-H. Canova
C. Jenny
Philippe Maingon
G. Klausner
Raymond Miralbell
I. Troussier
A. Lyothier
Y. Slama
M. Chea
Juliette Thariat
Raphael Jumeau
Julian Biau
E. Blais
Sol Agro et hydrosystème Spatialisation (SAS)
AGROCAMPUS OUEST-Institut National de la Recherche Agronomique (INRA)
Centre Jean Perrin
CRLCC Jean Perrin
Imagerie Moléculaire et Stratégies Théranostiques - Clermont Auvergne (IMoST)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Clermont Auvergne (UCA)
STMicroelectronics [Crolles] (ST-CROLLES)
CHU Pitié-Salpêtrière [APHP]
Département de Radiation oncologie, CGFL
Centre Régional de Lutte contre le cancer - Centre Georges-François Leclerc (CRLCC - CGFL)
Centre Jean Perrin [Clermont-Ferrand] (UNICANCER/CJP)
UNICANCER
Imagerie Moléculaire et Stratégies Théranostiques (IMoST)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Clermont Auvergne [2017-2020] (UCA [2017-2020])
CHU Pitié-Salpêtrière [AP-HP]
Sorbonne Université (SU)-Assistance publique - Hôpitaux de Paris (AP-HP) (AP-HP)
Centre Régional de Lutte contre le cancer Georges-François Leclerc [Dijon] (UNICANCER/CRLCC-CGFL)
UNICANCER-UNICANCER
Assistance publique - Hôpitaux de Paris (AP-HP) (AP-HP)-Sorbonne Université (SU)
Service de radiothérapie [Centre Georges-François Leclerc]
Source :
Cancer Radiothérapie, Cancer Radiothérapie, Elsevier Masson, 2019, 23 (3), pp.248-254. ⟨10.1016/j.canrad.2018.07.142⟩, Cancer/Radiothérapie, Cancer/Radiothérapie, Elsevier Masson, 2019, 23 (3), pp.248-254. ⟨10.1016/j.canrad.2018.07.142⟩
Publication Year :
2019
Publisher :
HAL CCSD, 2019.

Abstract

Installation and use of a new radiotherapy device require an adequate quality and safety policy. The process leading to the commissioning of an accelerator following the construction of a bunker includes, among other tasks, the installation of the accelerator, the verification of compliance with the specifications, the signature of the acceptance specification as well as the process of characterization and modeling of the accelerator before its clinical use. The emergence of modern radiotherapy techniques, such as intensity modulated conformational radiotherapy and stereotactic radiotherapy, has resulted in more complex quality controls. The purpose of this article is to explain the different stages of the implementation of innovative radiotherapy techniques and to specify their features.