A Low-Power High-Data-Transmission Multi-Lead ECG Acquisition Sensor System

Authors :
Ming-Hui Fan
Wei Zhang
Su-Ya Jiang
Chiung-An Chen
Patricia Angela R. Abu
Ming-Hui Guan
Shih-Lun Chen
Liang-Hung Wang
Source :
Sensors, Volume 19, Issue 22, Sensors, Vol 19, Iss 22, p 4996 (2019), Sensors (Basel, Switzerland)
Publication Year :
2019
Publisher :
Multidisciplinary Digital Publishing Institute, 2019.

Abstract

This study presents a low-power multi-lead wearable electrocardiogram (ECG) signal sensor system design that can simultaneously acquire the electrocardiograms from three leads, I, II, and V1. The sensor system includes two parts, an ECG test clothing with five electrode patches and an acquisition device. Compared with the traditional 12-lead wired ECG detection instrument, which limits patient mobility and needs medical staff assistance to acquire the ECG signal, the proposed vest-type ECG acquisition system is very comfortable and easy to use by patients themselves anytime and anywhere, especially for the elderly. The proposed study incorporates three methods to reduce the power consumption of the system by optimizing the micro control unit (MCU) working mode, adjusting the radio frequency (RF) parameters, and compressing the transmitted data. In addition, Huffman lossless coding is used to compress the transmitted data in order to increase the sampling rate of the acquisition system. It makes the whole system operate continuously for a long period of time and acquire abundant ECG information, which is helpful for clinical diagnosis. Finally, a series of tests were performed on the designed wearable ECG device. The results have demonstrated that the multi-lead wearable ECG device can collect, process, and transmit ECG data through Bluetooth technology. The ECG waveforms collected by the device are clear, complete, and can be displayed in real-time on a mobile phone. The sampling rate of the proposed wearable sensor system is 250 Hz per lead, which is dependent on the lossless compression scheme. The device achieves a compression ratio of 2.31. By implementing a low power design on the device, the resulting overall operational current of the device is reduced by 37.6% to 9.87 mA under a supply voltage of 2.1 V. The proposed vest-type multi-lead ECG acquisition device can be easily employed by medical staff for clinical diagnosis and is a suitable wearable device in monitoring and nursing the off-ward patients.

Details

Language :
English
ISSN :
14248220
Database :
OpenAIRE
Journal :
Sensors
Accession number :
edsair.doi.dedup.....4b2f00a1a3f1307bfdc806cb486d0790
Full Text :
https://doi.org/10.3390/s19224996