Back to Search
Start Over
Development of a multi-matrix LC–MS/MS method for urea quantitation and its application in human respiratory disease studies
- Source :
- Journal of Pharmaceutical and Biomedical Analysis. 133:96-104
- Publication Year :
- 2017
- Publisher :
- Elsevier BV, 2017.
-
Abstract
- In human respiratory disease studies, liquid samples such as nasal secretion (NS), lung epithelial lining fluid (ELF), or upper airway mucosal lining fluid (MLF) are frequently collected, but their volumes often remain unknown. The lack of volume information makes it hard to estimate the actual concentration of recovered active pharmaceutical ingredient or biomarkers. Urea has been proposed to serve as a sample volume marker because it can freely diffuse through most body compartments and is less affected by disease states. Here, we report an easy and reliable LC-MS/MS method for cross-matrix measurement of urea in serum, plasma, universal transfer medium (UTM), synthetic absorptive matrix elution buffer 1 (SAMe1) and synthetic absorptive matrix elution buffer 2 (SAMe2) which are commonly sampled in human respiratory disease studies. The method uses two stable-isotope-labeled urea isotopologues, [15N2]-urea and [13C,15N2]-urea, as the surrogate analyte and the internal standard, respectively. This approach provides the best measurement consistency across different matrices. The analyte extraction was individually optimized in each matrix. Specifically in UTM, SAMe1 and SAMe2, the unique salting-out assisted liquid-liquid extraction (SALLE) not only dramatically reduces the matrix interferences but also improves the assay recovery. The use of an HILIC column largely increases the analyte retention. The typical run time is 3.6min which allows for high throughput analysis.
- Subjects :
- Analyte
Bioanalysis
Respiratory Tract Diseases
Clinical Biochemistry
Pharmaceutical Science
Buffers
Tandem mass spectrometry
01 natural sciences
Analytical Chemistry
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
Tandem Mass Spectrometry
Drug Discovery
Humans
Urea
Carbon Radioisotopes
Chromatography, High Pressure Liquid
Spectroscopy
Active ingredient
Chromatography
Nitrogen Isotopes
Elution
Hydrophilic interaction chromatography
010401 analytical chemistry
Extraction (chemistry)
Reproducibility of Results
Culture Media
0104 chemical sciences
030228 respiratory system
chemistry
Subjects
Details
- ISSN :
- 07317085
- Volume :
- 133
- Database :
- OpenAIRE
- Journal :
- Journal of Pharmaceutical and Biomedical Analysis
- Accession number :
- edsair.doi.dedup.....4b475ad4b909910335a40e5cf97bdec3
- Full Text :
- https://doi.org/10.1016/j.jpba.2016.11.001