Back to Search Start Over

Development and Validation of a Simple and Rapid Ultrahigh-Performance Liquid Chromatography Tandem Spectrometry Method for the Quantification of Hydroxychloroquine in Plasma and Blood Samples in the Emergency Context of SARS-CoV-2 Pandemic

Authors :
Bruno Lacarelle
Romain Guilhaumou
Renée Ugdonne
Caroline Solas
Karine Barthélémy
Natalia Doudka
Manon Basso
Madeleine Giocanti
Olivier Blin
Hôpital de la Timone [CHU - APHM] (TIMONE)
Institut de Neurosciences des Systèmes (INS)
Aix Marseille Université (AMU)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Unité des Virus Emergents (UVE)
Institut de Recherche pour le Développement (IRD)-Aix Marseille Université (AMU)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Otten, Lisa
Source :
Therapeutic Drug Monitoring, Therapeutic Drug Monitoring, Lippincott, Williams & Wilkins, 2021, 43 (4), pp.570-576. ⟨10.1097/FTD.0000000000000836⟩
Publication Year :
2021
Publisher :
HAL CCSD, 2021.

Abstract

International audience; Therapeutic drug monitoring of hydroxychloroquine (HCQ) has been recommended to optimize the treatment of patients with COVID-19. The authors describe an ultrahigh-performance liquid chromatography tandem spectrometry method developed in a context of emergency, to analyze HCQ in both human plasma and blood samples. After adding the labeled internal standard and simple protein precipitation, plasma samples were analyzed using a C18 column. Blood samples required evaporation before analysis. The total chromatographic run time was 4 minutes (including 1.5 minutes of column equilibration). The assay was linear over the calibration range (r2 > 0.99) and up to 1.50 mcg/mL for the plasma samples (5.00 mcg/mL for the blood matrix). The limit of quantification was 0.0150 mcg/mL for plasma samples (0.05 mcg/mL blood matrix) with accuracy and precision ranging from 91.1% to 112% and from 0.750% to 11.1%, respectively. Intraday and interday precision and accuracy values were within 15.0%. No significant matrix effect was observed in the plasma or blood samples. This method was successfully applied to patients treated for COVID-19 infection. A simple and rapid ultrahigh-performance liquid chromatography tandem spectrometry method adapted to HCQ therapeutic drug monitoring in the context of SARS-CoV-2 infection was successfully developed and validated.

Details

Language :
English
ISSN :
01634356
Database :
OpenAIRE
Journal :
Therapeutic Drug Monitoring, Therapeutic Drug Monitoring, Lippincott, Williams & Wilkins, 2021, 43 (4), pp.570-576. ⟨10.1097/FTD.0000000000000836⟩
Accession number :
edsair.doi.dedup.....4b87d814d2fbfbe6645817d16c97f947