Light collection and pulse-shape discrimination in elongated scintillator cells for the PROSPECT reactor antineutrino experiment

Authors :
E. Romero
Chao Zhang
M. P. Mendenhall
J. J. Cherwinka
K. Gilje
H. Yao
A. Galindo-Uribarri
B. R. Littlejohn
Christopher B. Williams
J. Ashenfelter
X. Zhang
D. J. Dean
A. Bowes
Minfang Yeh
P. T. Surukuchi
H. R. Band
N.T. Stemen
J. K. Gaison
B. R. White
R. Sharma
M. V. Diwan
D. E. Jaffe
D. Davee
Rui-Lin Chu
D. A. Martinez Caicedo
C. D. Bryan
Xin Qian
Y-R Yen
L. Saldaña
G. Deichert
R. D. McKeown
B. Balantekin
C. White
G. Zangakis
A. Glenn
J. Wilhelmi
G. Barclay
B. W. Goddard
T. Wise
D. Berish
B. Viren
R. L. Varner
D. A. Dwyer
K. Commeford
T. J. Langford
Steven Sheets
R. Rosero
Jim Napolitano
S. Hans
Ke Han
D. Norcini
B. Heffron
Wei Wang
Nathaniel Bowden
R. Neilson
J. P. Brodsky
J. Dolph
M. J. Dolinski
Hans P. Mumm
T. Classen
C.D. Bass
K. M. Heeger
M. P. Green
B. Seilhan
Dmitry A. Pushin
P. E. Mueller
Source :
Journal of Instrumentation, vol 10, iss 11, Ashenfelter, J; Balantekin, B; Band, HR; Barclay, G; Bass, CD; Berish, D; et al.(2015). Light collection and pulse-shape discrimination in elongated scintillator cells for the PROSPECT reactor antineutrino experiment. Journal of Instrumentation, 10(11). doi: 10.1088/1748-0221/10/11/P11004. Lawrence Berkeley National Laboratory: Retrieved from: http://www.escholarship.org/uc/item/1cj4p7dz
Publication Year :
2015
Publisher :
eScholarship, University of California, 2015.

Abstract

A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been studied using gamma and spontaneous fission calibration sources deployed along the cell long axis. We also study neutron-gamma discrimination and light collection abilities for differing PMT and reflector configurations. Key design features for optimizing MeV-scale response and background rejection capabilities are identified.<br />Comment: 20 pages, 11 figures

Details

Database :
OpenAIRE
Journal :
Journal of Instrumentation, vol 10, iss 11, Ashenfelter, J; Balantekin, B; Band, HR; Barclay, G; Bass, CD; Berish, D; et al.(2015). Light collection and pulse-shape discrimination in elongated scintillator cells for the PROSPECT reactor antineutrino experiment. Journal of Instrumentation, 10(11). doi: 10.1088/1748-0221/10/11/P11004. Lawrence Berkeley National Laboratory: Retrieved from: http://www.escholarship.org/uc/item/1cj4p7dz
Accession number :
edsair.doi.dedup.....4c14e9cfb9da9a6818c87b96be9e9d85
Full Text :
https://doi.org/10.1088/1748-0221/10/11/P11004.