Back to Search Start Over

Quantification of cells with specific phenotypes I: Determination of CD4+ cell count per microliter in reconstituted lyophilized human PBMC prelabeled with anti‐CD4 FITC antibody

Quantification of cells with specific phenotypes I: Determination of CD4+ cell count per microliter in reconstituted lyophilized human PBMC prelabeled with anti‐CD4 FITC antibody

Authors :
Laura Revel
Andrea Engel
Rudolf J. Schneider
Tamara Lekishvili
Jörg Neukammer
Dinesh K. Dikshit
Bodo Roemer
Martin Kammel
Adolfas K. Gaigalas
Maria Paola Sassi
Sook-Kyung Kim
Marc-Olivier Baradez
Richard Stebbings
Lili Wang
Liam Whitby
Gerald E. Marti
Volker Ost
Fatima Abbasi
Maren Kuhne
Damian Marshall
Janet Sutherland
Manuela John
Wang Jing
Michael Braun
Maxim S Vonsky
Source :
Cytometry
Publication Year :
2015
Publisher :
Wiley, 2015.

Abstract

A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluated in the pilot study CCQM-P102. This study was conducted across 16 laboratories from eight countries to assess the ability of participants to quantify the CD4+ cell count of this reference material and to document cross-laboratory variability plus associated measurement uncertainties. Twelve different flow cytometer platforms were evaluated using a standard protocol that included calibration beads used to obtain quantitative measurements of CD4+ T cell counts. There was good overall cross-platform and counting method agreement with a grand mean of the laboratory calculated means of (301.7 ± 4.9) μL−1 CD4+ cells. Excluding outliers, greater than 90% of participant data agreed within ±15%. A major contribution to variation of sLL CD4+ cell counts was tube to tube variation of the calibration beads, amounting to an uncertainty of 3.6%. Variation due to preparative steps equated to an uncertainty of 2.6%. There was no reduction in variability when data files were centrally reanalyzed. Remaining variation was attributed to instrument specific differences. CD4+ cell counts obtained in CCQM-P102 are in excellent agreement and show the robustness of both the measurements and the data analysis and hence the suitability of sLL as a reference material for interlaboratory comparisons and external quality assessment. © 2015 The Authors. Published by Wiley Periodicals, Inc.

Details

ISSN :
15524930 and 15524922
Volume :
87
Database :
OpenAIRE
Journal :
Cytometry Part A
Accession number :
edsair.doi.dedup.....4c899269cf52d02279deceaa3cab56b1
Full Text :
https://doi.org/10.1002/cyto.a.22614