Sandblasted implants may have a lower risk of implant failure but not different marginal bone loss than machined implants
- Source :
- PLoS ONE
- Publication Year :
- 2019
-
Abstract
- Introduction Sandblasting is one of the oldest implant surface modifications to enhance osseointegration. Regarding its superiority over machined surface controversies still exist. Our objective was to compare implant failures (IF) and marginal bone level (MBL) changes between sandblasted and machined dental implants by a meta-analysis utilizing the available data. The PROSPERO registration number of the meta-analysis is CRD42018084190. Methods The systematic search was performed in Cochrane, Embase and Pubmed. Inclusion criteria included participants with neither systemic diseases, nor excessive alcohol consumption, nor heavy smoking. We calculated pooled Risk Ratio (RRs) with confidence intervals of 95% (CIs) for dichotomous outcomes (implant failure) and weighted mean difference (WMD) CIs of 95% for continuous outcomes (marginal bone level change). We applied the random effect model with DerSimonian-Laird estimation. I2 and chi2 tests were used to quantify statistical heterogeneity and gain probability-values, respectively. Results Literature search revealed 130 records without duplicates. Out of these, seven studies met the inclusion criteria and all were included in data synthesis, involving 362 sand-blasted and 360 machined implants. The results indicate that there is an 80% (RR = 0.2 95% CI:0.06–0.67; I2 = 0.0% p = 0.986) lower among sandblasted compared to machined implants after one year of use and 74% (RR = 0.26 95% CI:0.09–0.74; I2 = 0.0% p = 0.968) five years of use, respectively. In contrast, there is no significant difference in MBL (WMD:-0.10mm, 95% CI:-0.20, 0.01; p>0.05; I2 = 0.0%, p = 0.560 and WMD:-0.01mm, 95% CI:-0.12, 0.09; p>0.05; I2 = 26.2%, p = 0.258) between the two implant surfaces after one and five years of use. Conclusions This meta-analysis reveals that sandblasting is superior over machined surface in implant failure but not in marginal bone level in healthy subjects. It also points out the need for further randomized clinical trials with large sample size for objective determination of the clinical benefits of certain implant surface modifications.
- Subjects :
- Drug Research and Development
Medical Implants
Physiology
Dentistry
Bioengineering
Hemorrhage
Lower risk
Research and Analysis Methods
Pathology and Laboratory Medicine
Vascular Medicine
Database and Informatics Methods
Mathematical and Statistical Techniques
Signs and Symptoms
Osseointegration
Diagnostic Medicine
Medicine and Health Sciences
Medicine
Clinical Trials
Statistical Methods
Database Searching
General Dentistry
Titanium Implants
Dental Implants
Pharmacology
business.industry
Dental Implantation, Endosseous
Statistics
Implant failure
Biology and Life Sciences
Metaanalysis
Randomized Controlled Trials
Dental Prosthesis Design
Jaw
Physical Sciences
Engineering and Technology
Medical Devices and Equipment
Clinical Medicine
Anatomy
business
Physiological Processes
Head
Mathematics
Research Article
Biotechnology
Subjects
Details
- ISSN :
- 19434723
- Volume :
- 150
- Issue :
- 10
- Database :
- OpenAIRE
- Journal :
- Journal of the American Dental Association (1939)
- Accession number :
- edsair.doi.dedup.....4d85bcf2c5e3881f70f4128c3662795d