Back to Search
Start Over
The incidence and results of laser enhancement after cataract and refractive surgery with trifocal lens implantation
- Source :
- Biomedical Papers. 166:222-227
- Publication Year :
- 2022
- Publisher :
- Palacky University Olomouc, 2022.
-
Abstract
- Purpose. To evaluate the incidence of laser enhancement following cataract surgery and refractive lens exchange (RLE) with FineVision Micro F trifocal lens implantation (PhysIOL, Liege, Belgium). Methods. Retrospective study of patients who had undergone cataract or RLE surgery and had received a FineVision Micro F intraocular lens. Laser enhancement of residual refractive error was determined. Visual acuity (VA) assessments were performed before and after surgery: uncorrected distance VA (UCDVA), best-corrected distance VA (BCDVA), uncorrected near VA (UCNVA), plus preoperative and postoperative spherical equivalent (SE) assessments. Results. Of the 1129 eyes from 596 patients, 61 (5.4%) required laser enhancement to correct residual refractive error (by group: 30/679 eyes [4.4%] cataract; 31/450 eyes [6.9%] RLE). Eleven eyes received FemtoLASIK; 50 eyes received PRK. Mean UCDVA before laser enhancement was 0.26±0.19 logMAR and 0.24±0.14 in the FemtoLASIK and PRK groups, respectively. After laser enhancement, these were 0.04±0.05 logMAR and 0.13±0.19, respectively; BCDVA values were 0.00±0.00 logMAR in the FemtoLASIK group and 0.06±0.11 in the PRK group. Laser enhancement improved UCNVA (Jaeger) from 2-3 to 1-2 in both groups. Enhancement reduced preoperative SE of -0.39±0.99 D and -0.53±0.58 D (FemtoLASIK and PRK groups, respectively) to 0.24±0.36 D and 0.04±0.47 D. Conclusions. The FineVision Micro F trifocal lens is an effective solution for gaining increased spectacle independence. The incidence of residual refractive error requiring laser enhancement is low, and laser procedures are a safe and effective solution for improving the quality of vision and patient satisfaction. Synopsis. Laser enhancement rates and outcomes were determined following cataract / refractive lens exchange surgery that used a trifocal IOL. Enhancement was safe and effective and rates were low (5.4%).
- Subjects :
- Refractive error
medicine.medical_specialty
Visual acuity
genetic structures
medicine.medical_treatment
Intraocular lens
Prosthesis Design
General Biochemistry, Genetics and Molecular Biology
law.invention
Lens Implantation, Intraocular
law
Ophthalmology
Refractive surgery
medicine
Humans
Retrospective Studies
Phacoemulsification
business.industry
Incidence
Lasers
Incidence (epidemiology)
Capsule Opacification
Cataract surgery
Refractive Errors
medicine.disease
Laser
eye diseases
Lens (optics)
Patient Satisfaction
medicine.symptom
business
Subjects
Details
- ISSN :
- 18047521 and 12138118
- Volume :
- 166
- Database :
- OpenAIRE
- Journal :
- Biomedical Papers
- Accession number :
- edsair.doi.dedup.....4df1af03081195255acd1bb35d5489d9
- Full Text :
- https://doi.org/10.5507/bp.2021.010