Back to Search
Start Over
Digitale Mammographie mit hochauflösenden Speicherfolien (CR) versus digitaler Vollfeldmammographie (CCD) (DR): Mikrokalzifikationen und Herdbefunde – eine retrospektiv klinisch/histologische Analyse (n=102)
- Source :
- Senologie - Zeitschrift für Mammadiagnostik und -therapie. 2
- Publication Year :
- 2005
- Publisher :
- Georg Thieme Verlag KG, 2005.
-
Abstract
- PURPOSE: To determine the diagnostic accuracy of microcalcifications and focal lesions in a retrospective clinical-histological study using high-resolution digital phosphor storage plates (hard copy) and full-field digital mammography (hard copy). MATERIALS AND METHODS: From May 2003 to September 2003, 102 patients underwent digital storage plate mammography (CR), using a mammography unit (Mammomat 3000 N, Siemens) in combination with a high resolution (9 lp/mm) digital storage phosphor plate system (pixel size 50 microm) (Fuji/Siemens). After diagnosis and preoperative wire localization, full-field digital mammography (CCD) (DR) was performed with the same exposure parameters. The full-field digital mammography used a CCD-detector (SenoScan) (Fisher Imaging) with a resolution of 10 Ip/mm and a pixel size of 50 microm. Five investigators determined the diagnosis (BI-RADS I - V) retrospectively after the operation from randomly distributed mediolateral views (hard copy reading). These results were correlated with the final histology. RESULTS: The diagnostic accuracy of digital storage plate mammography (CR) and full-field digital mammography (CCD) (DR) was 73 % and 71 % for all findings (n = 102), 73 % and 71 % for microcalcifications (n = 51), and 72 % and 70 % for focal lesions (n = 51). The overall results showed no difference. CONCLUSION: Our findings indicate the equivalence of high-resolution digital phosphor storage plate mammography (CR) and full-field digital mammography (CCD) (DR).
- Subjects :
- medicine.medical_specialty
Digital mammography
medicine.diagnostic_test
Breast calcification
business.industry
Wire localization
Follow up studies
Diagnostic accuracy
Digital storage
Medicine
Mammography
Radiology, Nuclear Medicine and imaging
Radiographic Image Enhancement
Radiology
business
Nuclear medicine
Subjects
Details
- ISSN :
- 1611647X and 16116453
- Volume :
- 2
- Database :
- OpenAIRE
- Journal :
- Senologie - Zeitschrift für Mammadiagnostik und -therapie
- Accession number :
- edsair.doi.dedup.....4dfdc608714ccd0d5f5e7bd1f84a0d39
- Full Text :
- https://doi.org/10.1055/s-2005-917818