Back to Search
Start Over
Pedicle Morphology Using Computed Tomography-based Navigation System in Adolescent Idiopathic Scoliosis
- Source :
- Journal of Spinal Disorders & Techniques. 26:22-28
- Publication Year :
- 2013
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2013.
-
Abstract
- Study design/setting Retrospective study. Objective The purpose of this study was to use multidimensional analysis with a computed tomography (CT)-based navigation system to measure the outer cortical diameter and the maximum screw trajectory length of the pedicle of the thoracic and lumbar regions of the spine in adolescent idiopathic scoliosis (AIS) patients. Another objective was to identify pedicles that require cautious insertion of screws. Summary of background data Pedicle diameter in AIS patients was narrower on the concave side of the scoliotic curve. Many researchers have measured pedicle diameter and length of AIS patients by using standard CT or magnetic resonance imaging (MRI), but only few have used 3-dimensional imaging, especially CT-based navigation. Methods Fifteen patients with right-side thoracic AIS who underwent pedicle screw fixation were studied. A CT-based navigation system was used to measure the pedicle diameter, defined as the widest outer cortical diameter at the narrowest part of the pedicle. Moreover, the maximum pedicle screw trajectory length was measured as the distance between the posterior cortical entry point of the pedicle screw and the anterior vertebral cortex in line with the axis of the pedicle between T1 and L5. In addition, the values of each parameter taken using the CT navigation system and the standard axial CT were compared. Results Pedicles on the concave side of the main thoracic curve apex and proximal thoracic curve tended to have the narrowest diameters. The mean length of the longest screw that could be fixed was longer on the right side, except for T8 and T9. Our data showed screw size feasibility as follows: 25 or 30 mm screws were feasible from T1 to T5; 30 or 35 mm screws, from T6 to T12; and 35 or 40 mm screws, from L1 to L5. Pedicle diameter measured by the CT navigation system was larger than that measured by standard axial CT. Left-side pedicle length measured by the CT navigation system was lesser than that measured by standard axial CT. Conclusions Pedicle diameter in patients with AIS is narrower on the concave side of the scoliotic curve, and therefore, caution should be exercised during screw insertion on the concave side.
- Subjects :
- Male
medicine.medical_specialty
Adolescent
Bone Screws
Computed tomography
Idiopathic scoliosis
Concave side
Lumbar
medicine
Humans
Orthopedics and Sports Medicine
Pedicle screw fixation
Child
medicine.diagnostic_test
business.industry
Navigation system
Magnetic resonance imaging
Spinal Fusion
Treatment Outcome
Scoliosis
Surgery, Computer-Assisted
Female
Surgery
Neurology (clinical)
Radiology
Tomography
Tomography, X-Ray Computed
business
Nuclear medicine
Subjects
Details
- ISSN :
- 15360652
- Volume :
- 26
- Database :
- OpenAIRE
- Journal :
- Journal of Spinal Disorders & Techniques
- Accession number :
- edsair.doi.dedup.....4e1ded9cb7e6f06bcb1a5c558f8f6bf6
- Full Text :
- https://doi.org/10.1097/bsd.0b013e31823162ef