- Background: The uncemented collum femoris-preserving (CFP) stem offers preservation of the femoral neck and a more conservative soft tissue resection, which may facilitate a more normal walking pattern. We used gait analysis to evaluate if patients operated with a CFP stem showed more favourable hip kinematics and kinetics when compared with a group of patients operated with a conventional uncemented stem. Methods: 44 patients randomised to receive either a CFP or a Corail stem were studied and were operated using a direct lateral incision. Gait analysis was performed 2 years after the operation with a 12-camera motion capture system and 2 force plates. Hip kinematics and kinetics were analysed and 66 subjects served as controls. Results: None of the variables: speed, stride, cadence and stance showed any statistical significant difference between the 2 study groups. Neither did the hip kinematics and kinetics. Compared to controls, patients operated with the CFP stem showed an increased stance (62.5% vs. 61.1%, p < 0.006) and decreased hip abduction (−2.1° vs. −6.5°). Patients operated with the Corail stem showed decreased speed (1.18 vs. 1.23 m/second), and stride length (1.26 vs. 1.33 m), decreased hip extension (−7.5° vs. −12.8°) and range of hip flexion/extension (38° vs. 40.9°), as well as their hip adduction that was increased (6.3° vs. 4°), whereas their hip abduction was reduced (−2.8° vs. −6.5°), ( p < 0.004) compared to the controls. Conclusions: Use of a CFP stem did not significantly influence any of the gait parameters studied when compared to a standard stem, but still both stems studied were associated with gait deviations when compared to controls. Whether these differences could be attributed to the stem used, the underlying hip disease, or both is still unknown.
- Subjects :
- medicine.medical_specialty
Arthroplasty, Replacement, Hip
medicine.medical_treatment
Walking
Resection
03 medical and health sciences
0302 clinical medicine
Gait (human)
medicine
Humans
Orthopedics and Sports Medicine
Gait
Femoral neck
030222 orthopedics
Femur Neck
business.industry
Soft tissue
030229 sport sciences
Arthroplasty
Biomechanical Phenomena
Surgery
medicine.anatomical_structure
Collum femoris
Gait pattern
Gait Analysis
business
Total hip arthroplasty
Subjects
Details
- ISSN :
- 17246067 and 11207000
- Volume :
- 32
- Database :
- OpenAIRE
- Journal :
- HIP International
- Accession number :
- edsair.doi.dedup.....4ede0bdd09d2b4fb30bcfe4e15a7bc2a
- Full Text :
- https://doi.org/10.1177/1120700020967645