A modified LVAD technique to augment caval and pulmonary arterial blood flow in the 'failing Fontan' circulation
- Source :
- Journal of Cardiac Surgery. 32:126-132
- Publication Year :
- 2017
- Publisher :
- Hindawi Limited, 2017.
-
Abstract
- Background There are minimal circulatory support options for patients with a failing Fontan. The Heartmate II (HMII) left ventricular assist device (Thoratec, Bedford, MA) in its packaged state cannot augment caval/pulmonary arterial blood flow. Aim We hypothesized that a modified HMII pump could augment caval and pulmonary arterial blood flow. Methods A bifurcated ringed Gore-Tex graft (W. L. Gore & Associates, Flagstaff, AZ) was sewn to the HMII inflow, and the outflow graft transected and tapered from 16 mm to 8 mm in diameter. In three sheep, the inflow and outflow grafts were anastomosed end-to-side to both cava and the pulmonary artery. Results Following baseline measurements, the pump speed was increased to 8000 revolutions per minute (RPMs). Compared to baseline, at 8000 RPMs, there were no significant differences in mean arterial, central venous, or pulmonary arterial pressure. However, there was a significant decrease in right ventricular diastolic diameter (3.1 ± 0.1 vs. 1.8 ± 0.2 cm, R = 0.6, p = 0.02) and similarly a decrease in pulmonary arterial pulse pressure (8.5 ± 2.1 vs. 2.1 ± 2.9 mmHg, p = 0.01). As pump speed increased, there was a corresponding increase in pump flow and power, with a decrease in pulsatility index. Conclusions These findings suggest that the HMII may be modified to provide caval/pulmonary circulatory support for the failing Fontan circulation.
- Subjects :
- Heart Defects, Congenital
Pulmonary and Respiratory Medicine
Pulmonary Circulation
Vena Cava, Superior
medicine.medical_treatment
Diastole
Pulmonary Artery
030204 cardiovascular system & hematology
Fontan Procedure
Prosthesis Design
Ventricular Function, Left
03 medical and health sciences
0302 clinical medicine
medicine.artery
medicine
Animals
Computer Simulation
Arterial pulse pressure
Sheep
business.industry
Models, Cardiovascular
Arterial blood flow
Disease Models, Animal
030228 respiratory system
Anesthesia
Ventricular assist device
Pulmonary artery
Circulatory system
Ventricular Function, Right
cardiovascular system
Feasibility Studies
Surgery
Heart-Assist Devices
Augment
Cardiology and Cardiovascular Medicine
business
Blood Flow Velocity
Revolutions per minute
Subjects
Details
- ISSN :
- 08860440
- Volume :
- 32
- Database :
- OpenAIRE
- Journal :
- Journal of Cardiac Surgery
- Accession number :
- edsair.doi.dedup.....4f391c220f83351a7a2559ccdc29b20a
- Full Text :
- https://doi.org/10.1111/jocs.12931