Impact of dose engine algorithm in pencil beam scanning proton therapy for breast cancer
- Source :
- Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 50
- Publication Year :
- 2018
-
Abstract
- Purpose Proton therapy for the treatment of breast cancer is acquiring increasing interest, due to the potential reduction of radiation-induced side effects such as cardiac and pulmonary toxicity. While several in silico studies demonstrated the gain in plan quality offered by pencil beam scanning (PBS) compared to passive scattering techniques, the related dosimetric uncertainties have been poorly investigated so far. Methods Five breast cancer patients were planned with Raystation 6 analytical pencil beam (APB) and Monte Carlo (MC) dose calculation algorithms. Plans were optimized with APB and then MC was used to recalculate dose distribution. Movable snout and beam splitting techniques (i.e. using two sub-fields for the same beam entrance, one with and the other without the use of a range shifter) were considered. PTV dose statistics were recorded. The same planning configurations were adopted for the experimental benchmark. Dose distributions were measured with a 2D array of ionization chambers and compared to APB and MC calculated ones by means of a γ analysis (agreement criteria 3%, 3 mm). Results Our results indicate that, when using proton PBS for breast cancer treatment, the Raystation 6 APB algorithm does not allow obtaining sufficient accuracy, especially with large air gaps. On the contrary, the MC algorithm resulted into much higher accuracy in all beam configurations tested and has to be recommended. Conclusions Centers where a MC algorithm is not yet available should consider a careful use of APB, possibly combined with a movable snout system or in any case with strategies aimed at minimizing air gaps.
- Subjects :
- Materials science
Dose calculation
Monte Carlo method
Biophysics
General Physics and Astronomy
Breast Neoplasms
Dose distribution
Beam splitting
Radiation Dosage
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Breast cancer
medicine
Proton Therapy
Humans
Radiology, Nuclear Medicine and imaging
Pencil-beam scanning
Proton therapy
Phantoms, Imaging
Radiotherapy Planning, Computer-Assisted
Radiotherapy Dosage
General Medicine
medicine.disease
030220 oncology & carcinogenesis
Algorithm
Beam (structure)
Algorithms
Subjects
Details
- ISSN :
- 1724191X
- Volume :
- 50
- Database :
- OpenAIRE
- Journal :
- Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
- Accession number :
- edsair.doi.dedup.....509bedfdca9c445f8fa90638a5be25aa