Back to Search
Start Over
Simultaneous dual-isotope solid-state detector SPECT for improved tracking of white blood cells in suspected endocarditis
- Source :
- European heart journal. 38(6)
- Publication Year :
- 2015
-
Abstract
- Aims High-energy resolution and sensitivity of novel cadmium-zinc-telluride (CZT) detector equipped SPECT systems facilitate simultaneous imaging of multiple isotopes and may enhance the detection of molecular/cellular signals. This may refine the detection of endocarditis. This study was designed to determine the feasibility and diagnostic accuracy of simultaneous imaging of inflammation with 111In-labeled white blood cells (WBCs) and myocardial perfusion with 99mTc-sestamibi, for localization of WBCs relative to the valve plane in suspected endocarditis. Methods and results A dedicated cardiac CZT camera (Discovery 530c, GE Healthcare) was employed. Anthropomorphic thorax phantom studies were followed by clinical studies in 34 patients with suspected infection of native valves ( n = 12) or implants ( n = 22). Simultaneous 111In-WBC/99mTc perfusion imaging was performed, and compared with standard 111In-WBC planar scintigraphy and SPECT-CT. Phantom studies ruled out significant radioisotope crosstalk. Downscatter on 99mTc images was not observed for 111In activity as high as 2.5*99mTc activity. In patients, image quality was superior for CZT imaging vs. conventional SPECT-CT and planar scintigraphy ( P < 0.01). Cadmium-zinc-telluride dual isotope imaging improved reader confidence for detection of inflammatory foci. Diagnostic accuracy based on surgery or Duke Criteria during follow-up was highest for CZT imaging ( P < 0.001). Conclusion Novel CZT SPECT technology improves the accuracy of molecular/cellular cardiac imaging. Simultaneous multi-isotope imaging with 111In and 99mTc is feasible and aids in the workup of suspected endocarditis.
- Subjects :
- Male
Technetium Tc 99m Sestamibi
medicine.medical_specialty
Image quality
Perfusion scanning
030204 cardiovascular system & hematology
Single-photon emission computed tomography
Sensitivity and Specificity
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Medical imaging
medicine
Leukocytes
Endocarditis
Humans
Cardiac imaging
Observer Variation
Tomography, Emission-Computed, Single-Photon
medicine.diagnostic_test
business.industry
Phantoms, Imaging
Indium Radioisotopes
Middle Aged
medicine.disease
Female
Radiology
Radiopharmaceuticals
Cardiology and Cardiovascular Medicine
business
Nuclear medicine
Perfusion
Subjects
Details
- ISSN :
- 15229645
- Volume :
- 38
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- European heart journal
- Accession number :
- edsair.doi.dedup.....50c8ea031eb21ae6d771c1a7d9145449