Back to Search
Start Over
Backside polyethylene wear in reverse shoulder arthroplasty
- Source :
- Journal of Shoulder and Elbow Surgery. 31:545-552
- Publication Year :
- 2022
- Publisher :
- Elsevier BV, 2022.
-
Abstract
- Aseptic loosening from implant-associated osteolysis in reverse shoulder arthroplasty (RSA) may contribute to premature implant failure. Although articular side polyethylene (PE) damage has been well documented in the literature, no studies to date have investigated backside wear in RSA. The aims of this investigation were to (1) document and compare the damage between the backside and articular surface in explanted RSA components, (2) assess whether certain quadrants have a greater propensity for damage, and (3) report the most common mode(s) of backside PE damage.Twenty-one RSA humeral liners retrieved during revision procedures between 2005 and 2014 were included for analysis. The mean time between implantation and extraction was 16 months (10 days-88 months). Diagnoses at the time of revision included dislocation (10), infection (4), mechanical failure (3), loosening (2), and unknown (2). Liners were examined under light microscopy (×10-30 magnification) and damage on the articular and backside of the liner surface was graded using the modified Hood score. The location and damage modality were compared between the articular side and backside of the implant.Damage was noted on the articular surfaces of all 21 liners and on the backside surface of 20 liners. The total damage in all the quadrants was higher on the articular surface than on the backside of the component, with a mean difference in total quadrant damage scores of 11.74 ± 3.53 (P.001). There was no difference in damage among the quadrants on the backside (P = .44) or the articular surface (P = .08). The articular side exhibited greater scratching, abrasion, and surface deformation than the backside (P.001).This short-term retrieval study demonstrated that backside PE damage occurs on the humeral component of RSA implants. There was greater damage to the articular side of the liner but wear to the backside was present in almost all liners. The clinical importance of backside wear in RSA and its overall contribution to PE particulate disease and osteolysis needs further investigation.
- Subjects :
- musculoskeletal diseases
Osteolysis
medicine.medical_treatment
Aseptic loosening
Dentistry
Reverse shoulder
Prosthesis Design
chemistry.chemical_compound
Humans
Medicine
Orthopedics and Sports Medicine
business.industry
Implant failure
General Medicine
Articular surface
Polyethylene
medicine.disease
Arthroplasty
Prosthesis Failure
chemistry
Arthroplasty, Replacement, Shoulder
Surgery
Implant
business
Subjects
Details
- ISSN :
- 10582746
- Volume :
- 31
- Database :
- OpenAIRE
- Journal :
- Journal of Shoulder and Elbow Surgery
- Accession number :
- edsair.doi.dedup.....50d7e13697f0bddd404273cf6749ce0a