Back to Search
Start Over
Simultaneous determination of iprodione, procymidone, and chlorflurenol in lake water and wastewater matrices by GC-MS after multivariate optimization of binary dispersive liquid-liquid microextraction
- Source :
- Environmental Monitoring and Assessment. 190
- Publication Year :
- 2018
- Publisher :
- Springer Science and Business Media LLC, 2018.
-
Abstract
- This study reports the optimization of a binary dispersive liquid-liquid microextraction method for the determination of iprodione, procymidone, and chlorflurenol by gas chromatography mass spectrometry. The study was aimed at using two extraction solvents to increase the extraction efficiency of all analytes. The binary solvents recorded results higher than the mono-solvents. After examining the effects of main experimental parameters and their interactions by analysis of variance, 200 µL of binary mixture (dichloromethane and 1,2-dichloroethane), 2.5 mL of ethanol, and 15 s vortex were obtained as optimum parameters. The detection and quantification limits calculated for the analytes were found to be between 0.30–1.6 and 1.0–5.3 ng/mL, respectively. Enhancement in detection power calculated as a ratio of the binary extraction detection limit to the detection limit of direct GC-MS analysis was 105-, 214-, and 233-fold for chlorflurenol, iprodione, and procymidone, respectively. In order to check the accuracy of the developed method, recovery study was performed. Water sampled from a lake and two wastewater samples from treatment facilities were spiked at two concentrations, and the percent recovery calculated for the samples ranged between 87 and 116%. These results confirmed the suitability of the method to real samples for accurate determination of the analytes at trace levels. © 2018, Springer Nature Switzerland AG.
- Subjects :
- Analyte
Liquid Phase Microextraction
Wastewater
010501 environmental sciences
Management, Monitoring, Policy and Law
01 natural sciences
Gas Chromatography-Mass Spectrometry
Bridged Bicyclo Compounds
chemistry.chemical_compound
Limit of Detection
Binary solvent extraction
0105 earth and related environmental sciences
General Environmental Science
Dichloromethane
Detection limit
Fluorenes
Chromatography
Iprodione
DLLME
Hydantoins
010401 analytical chemistry
Extraction (chemistry)
General Medicine
Aminoimidazole Carboxamide
Pollution
Experimental design
0104 chemical sciences
Pesticide
Lakes
chemistry
Solvents
Procymidone
GC-MS
Gas chromatography–mass spectrometry
Water Pollutants, Chemical
Environmental Monitoring
Subjects
Details
- ISSN :
- 15732959 and 01676369
- Volume :
- 190
- Database :
- OpenAIRE
- Journal :
- Environmental Monitoring and Assessment
- Accession number :
- edsair.doi.dedup.....5208bc11686694311716040e7cffab93
- Full Text :
- https://doi.org/10.1007/s10661-018-6961-3