Benchmarking procedure for full-scale activated sludge plants

Authors :
G. van Straten
Karel J. Keesman
Henri Spanjers
A. Abusam
Source :
Control Engineering Practice 12 (2004) 3, Control Engineering Practice, 12(3), 315-322
Publication Year :
2004
Publisher :
Elsevier BV, 2004.

Abstract

To enhance development and acceptance of new control strategies, a standard simulation benchmarking methodology to evaluate the performance of wastewater treatment plants has recently been proposed. The proposed methodology is, however, for a typical plant and that works under typical loading and environmental conditions. Thus, benchmarking a full-scale plant working under different situations is still a problem that needs to be solved. This paper proposes a data based approach to benchmark any specific full-scale activated sludge plant used for carbon and nitrogen removal and using real design, operational and performance data. The advantage of the proposed approach over the "one-typical-plant" approach, is that it takes into account the very specific design and operational characteristics of the plant that will be benchmarked. A real-world illustrative example is also presented in this paperTo enhance development and acceptance of new control strategies, a standard simulation benchmarking methodology to evaluate the performance of wastewater treatment plants has recently been proposed. The proposed methodology is, however, for a typical plant and that works under typical loading and environmental conditions. Thus, benchmarking a full-scale plant working under different situations is still a problem that needs to be solved. This paper proposes a data based approach to benchmark any specific full-scale activated sludge plant used for carbon and nitrogen removal and using real design, operational and performance data. The advantage of the proposed approach over the "one-typical-plant" approach, is that it takes into account the very specific design and operational characteristics of the plant that will be benchmarked. A real-world illustrative example is also presented in this paper. (C) 2003 Elsevier Science Ltd. All rights reserved.

Details

ISSN :
09670661
Volume :
12
Database :
OpenAIRE
Journal :
Control Engineering Practice
Accession number :
edsair.doi.dedup.....521c17f0b2cc8b942e930d148971b28f
Full Text :
https://doi.org/10.1016/s0967-0661(03)00102-3