Fully Automatic Sliding Motion Compensated and Simultaneous 4D-CBCT via Bilateral Filtering
- Source :
- Frontiers in Oncology, Frontiers in Oncology, Vol 10 (2021)
- Publication Year :
- 2021
- Publisher :
- Frontiers Media S.A., 2021.
-
Abstract
- PurposeTo incorporate the bilateral filtering into the Deformable Vector Field (DVF) based 4D-CBCT reconstruction for realizing a fully automatic sliding motion compensated 4D-CBCT.Materials and MethodsInitially, a motion compensated simultaneous algebraic reconstruction technique (mSART) is used to generate a high quality reference phase (e.g. 0% phase) by using all phase projections together with the initial 4D-DVFs. The initial 4D-DVF were generated via Demons registration between 0% phase and each other phase image. The 4D-DVF will then kept updating by matching the forward projection of the deformed high quality 0% phase with the measured projection of the target phase. The loss function during this optimization contains an projection intensity difference matching criterion plus a DVF smoothing constrain term. We introduce a bilateral filtering kernel into the DVF constrain term to estimate the sliding motion automatically. The bilateral filtering kernel contains three sub-kernels: 1) an spatial domain Guassian kernel; 2) an image intensity domain Guassian kernel; and 3) a DVF domain Guassian kernel. By choosing suitable kernel variances, the sliding motion can be extracted. A non-linear conjugate gradient optimizer was used. We validated the algorithm on a non-uniform rotational B-spline based cardiac-torso (NCAT) phantom and four anonymous patient data. For quantification, we used: 1) the Root-Mean-Square-Error (RMSE) together with the Maximum-Error (MaxE); 2) the Dice coefficient of the extracted lung contour from the final reconstructed images and 3) the relative reconstruction error (RE) to evaluate the algorithm's performance.ResultsFor NCAT phantom, the motion trajectory's RMSE/MaxE are 0.796/1.02 mm for bilateral filtering reconstruction; and 2.704/4.08 mm for original reconstruction. For patient pilot study, the 4D-Dice coefficient obtained with bilateral filtering are consistently higher than that without bilateral filtering. Meantime several image content such as the rib position, the heart edge definition, the fibrous structures all has been better corrected with bilateral filtering.ConclusionWe developed a bilateral filtering based fully automatic sliding motion compensated 4D-CBCT scheme. Both digital phantom and initial patient pilot studies confirmed the improved motion estimation and image reconstruction ability. It can be used as a 4D-CBCT image guidance tool for lung SBRT treatment.
- Subjects :
- Cancer Research
deformable vector fields
Computer science
Iterative reconstruction
lcsh:RC254-282
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Motion estimation
sliding motion
Computer vision
Projection (set theory)
Original Research
business.industry
bilateral filtering
simultaneous reconstruction
lcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
Simultaneous Algebraic Reconstruction Technique
Kernel (image processing)
Oncology
030220 oncology & carcinogenesis
Bilateral filter
Artificial intelligence
business
4D-CBCT
Smoothing
Subjects
Details
- Language :
- English
- ISSN :
- 2234943X
- Volume :
- 10
- Database :
- OpenAIRE
- Journal :
- Frontiers in Oncology
- Accession number :
- edsair.doi.dedup.....52386693b8f1228188721e4811ac5f2b