- To evaluate the accuracy of 3D models of the aortic-root generated from non-contrast cardiac magnetic resonance (CMR). Data were retrospectively collected from 30 consecutive patients who underwent surgical aortic valve replacement and had available records of both intra-operative assessment and pre-surgery annulus assessment by cardiovascular computed tomography (CCT) and CMR. The 3D models were independently segmented, modelled and printed by two blinded “manufacturers”. The measurements on the models were carried out by two cardiac surgeons with Hegar dilator. Data were analyzed with non-parametric tests. There was no significant intra- or inter-observer variability (p ≥ 0.13). The agreement between the diameter of the 3D model derived from CMR images and either the anatomical reference of the intraoperative measurement (p = 0.10, r = 0.97) or the radiological reference of the 3D model generated from CCT (p = 0.71, r = 0.92) was very good. The process of segmentation plus the post-processing was about 17 ± 2 min for a model created by CMR, significantly higher than a model created from CCT (7 ± 2 min; p
- Subjects :
- Aortic valve
Male
Time Factors
030204 cardiovascular system & hematology
Cardiovascular
030218 nuclear medicine & medical imaging
Workflow
Transcatheter Aortic Valve Replacement
03 medical and health sciences
0302 clinical medicine
Aortic valve replacement
Models
Predictive Value of Tests
Multidetector Computed Tomography
medicine
80 and over
Humans
Radiology, Nuclear Medicine and imaging
Cardiac skeleton
Cardiac imaging
Aged
Retrospective Studies
Aged, 80 and over
medicine.diagnostic_test
business.industry
Models, Cardiovascular
Reproducibility of Results
Magnetic resonance imaging
3D printing
Aortic Valve Stenosis
medicine.disease
Magnetic Resonance Imaging
medicine.anatomical_structure
Predictive value of tests
Aortic valve stenosis
Aortic Valve
Three-Dimensional
Printing, Three-Dimensional
cardiovascular system
Printing
Female
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
Cardiac magnetic resonance
Transcatheter aortic valve replacement
Subjects
Details
- ISSN :
- 18758312
- Volume :
- 36
- Issue :
- 10
- Database :
- OpenAIRE
- Journal :
- The international journal of cardiovascular imaging
- Accession number :
- edsair.doi.dedup.....5266863fa3e532a5e8aba748d47bb032