Back to Search Start Over

An investigation of dynamical metal transfer in GMAW—Effects of argon shielding gas

Authors :
Yoke-Rung Wong
Shih-Fu Ling
School of Mechanical and Aerospace Engineering
Source :
Journal of Materials Processing Technology. 214:106-111
Publication Year :
2014
Publisher :
Elsevier BV, 2014.

Abstract

The unbalance radial electromagnetic force was firstly obtained by measuring the real-time input electrical impedance of GMAW. This force acts as an attaching force because it pushes the droplet aside of the welding wire and sticks on the tip of welding wire as result of surface tension force. In spray transfer mode, lower unbalance radial electromagnetic force was observed when argon shielding gas was used. The finding presented in this paper is contrary to the literature which reported that higher electromagnetic force is desirable for faster transfer rate of droplets in spray transfer mode. Accepted version

Details

ISSN :
09240136
Volume :
214
Database :
OpenAIRE
Journal :
Journal of Materials Processing Technology
Accession number :
edsair.doi.dedup.....5288509ca0bd016ce6e8a4a80fb2c81f
Full Text :
https://doi.org/10.1016/j.jmatprotec.2013.08.003