Back to Search Start Over

Examination of a Method to Determine the Reference Region for Calculating the Specific Binding Ratio in Dopamine Transporter Imaging

Authors :
Ayumi Watanabe
Yuji Asano
Takanobu Tokushige
Hiroki Miyatake
Yusuke Inoue
Kei Kikuchi
Source :
Japanese Journal of Radiological Technology. 73:291-297
Publication Year :
2017
Publisher :
Japanese Society of Radiological Technology, 2017.

Abstract

The specific binding ratio (SBR) was first reported by Tossici-Bolt et al. for quantitative indicators for dopamine transporter (DAT) imaging. It is defined as the ratio of the specific binding concentration of the striatum to the non-specific binding concentration of the whole brain other than the striatum. The non-specific binding concentration is calculated based on the region of interest (ROI), which is set 20 mm inside the outer contour, defined by a threshold technique. Tossici-Bolt et al. used a 50% threshold, but sometimes we couldn't define the ROI of non-specific binding concentration (reference region) and calculate SBR appropriately with a 50% threshold. Therefore, we sought a new method for determining the reference region when calculating SBR. We used data from 20 patients who had undergone DAT imaging in our hospital, to calculate the non-specific binding concentration by the following methods, the threshold to define a reference region was fixed at some specific values (the fixing method) and reference region was visually optimized by an examiner at every examination (the visual optimization method). First, we assessed the reference region of each method visually, and afterward, we quantitatively compared SBR calculated based on each method. In the visual assessment, the scores of the fixing method at 30% and visual optimization method were higher than the scores of the fixing method at other values, with or without scatter correction. In the quantitative assessment, the SBR obtained by visual optimization of the reference region, based on consensus of three radiological technologists, was used as a baseline (the standard method). The values of SBR showed good agreement between the standard method and both the fixing method at 30% and the visual optimization method, with or without scatter correction. Therefore, the fixing method at 30% and the visual optimization method were equally suitable for determining the reference region.

Details

ISSN :
18814883 and 03694305
Volume :
73
Database :
OpenAIRE
Journal :
Japanese Journal of Radiological Technology
Accession number :
edsair.doi.dedup.....537614ceea99e696a9954bc60b3816c6
Full Text :
https://doi.org/10.6009/jjrt.2017_jsrt_73.4.291