Sensitivity and Spatial Resolution of Transvenous Leads in Implantable Cardioverter Defibrillator
- Source :
- IEEE Transactions on Biomedical Engineering. 56:2773-2781
- Publication Year :
- 2009
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2009.
-
Abstract
- It has been previously documented that the main features and sensing performance of electrograms (EGMs) recorded in implantable cardioverter defibrillators (ICDs) depend on lead configuration. Although this dependence has been ascribed to differences in lead sensitivity and spatial resolution, the quantification of these two properties on ICD has not yet been attempted. In this paper, an operative framework to study the spatial resolution of ICD transvenous leads is presented. We propose to quantify the spatial resolution of ICD transvenous leads based on a new characterization called lead resolution volume (ResV). We analyzed the sensitivity distribution and the ResV of two unipolar (tip-can and coil-can ) and two bipolar (true or tip-ring and integrated or tip-coil) ICD transvenous lead configurations. A detailed 3-D model of the human thorax based on the visible human man dataset was used to compute the lead sensitivity and computer simulations of simple cardiac dynamics were used to quantify the ResV. Differences in the sensitivity distribution throughout the ventricular myocardium (VM) were observed for each lead configuration. In our computer model of the human thorax, the ResV was found to comprise 7%, 35%, 45%, and 70% of the VM for true bipolar, integrated bipolar, tip-can unipolar, and coil-can unipolar ICD leads, respectively. Furthermore, our analysis shows that the spatial resolution depends on both lead sensitivity and cardiac dynamics, and therefore, it can vary for different heart rhythms.
- Subjects :
- Thorax
medicine.diagnostic_test
Computer science
medicine.medical_treatment
Models, Cardiovascular
Biomedical Engineering
Reproducibility of Results
Implantable cardioverter-defibrillator
Sensitivity and Specificity
Defibrillators, Implantable
Electrodes, Implanted
Transvenous lead
Ventricular myocardium
Electrocardiography
Heart Conduction System
Heart Rate
medicine
Humans
Computer Simulation
Diagnosis, Computer-Assisted
Sensitivity (control systems)
Lead (electronics)
Image resolution
Biomedical engineering
Subjects
Details
- ISSN :
- 15582531 and 00189294
- Volume :
- 56
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Biomedical Engineering
- Accession number :
- edsair.doi.dedup.....538a2bdd8a357e7afa9d172ba4086f95
- Full Text :
- https://doi.org/10.1109/tbme.2009.2027425