Abstract

Introduction: Vomiting and regurgitation are commonly encountered in out-of-hospital cardiac arrest (OHCA), with a reported incidence of 20-30%. This is of concern since patients who have suffered an OHCA are already in extremis. If standard suctioning techniques are not sufficient to maintain a clear airway and provide ventilation, then these patients will die, irrespective of the quality of chest compressions and the timeliness of defibrillation. This study aimed to determine whether a short teaching session of the suction assisted laryngoscopy and airway decontamination (SALAD) technique improved paramedics' ability to successfully intubate a contaminated airway. Methods: A modified airway manikin with the oesophagus connected to a reservoir of 'vomit', and a bilge pump capable of propelling the vomit up into the oropharynx, was used to simulate a soiled airway. The intervention consisted of a brief SALAD training session with a demonstration and opportunity to practice. Participants were randomly allocated into two groups: AAB, who made two pre-training intubation attempts and one post-training attempt, and ABB, who made one pre-training and two post-training attempts, to adjust for improvement in performance due to repetition. Results: In this manikin study, following a brief SALAD training session, more paramedics were able to intubate a soiled airway on their first attempt, compared to those without training (90.2% vs. 53.7%, difference of 36.6%, 95% CI 24-49.1%, p < 0.001). In addition, the mean difference in time taken to perform a successful intubation between groups was statistically significant for attempts 1 and 2 (mean difference 11.71 seconds, 95% CI 1.95-21.47 seconds, p = 0.02), but not attempts 1 and 3 (mean difference -2.52 seconds, 95% CI -11.64-6.61 seconds, p = 0.58). This result is likely to be confounded by the use of tracheal suction, which only occurred in the post-training attempts and added additional time to the intubation attempts. There was no statistically significant difference in success rates on the third attempt between AAB and ABB (89.0% vs. 86.6%, difference 2.4%, 95% CI 7.6-12.4%, p = 0.63). Conclusion: In this study, the use of the SALAD technique significantly improved first attempt success rates when paramedics were intubating a simulated soiled airway.

Details

Language :
English
ISSN :
14784726
Database :
OpenAIRE
Journal :
Br Paramed J
Accession number :
edsair.doi.dedup.....57c161d377c4a703d8bec1b7621346ba