Back to Search
Start Over
Handheld motion stabilized laser speckle imaging
- Source :
- Biomedical optics express, vol 10, iss 10
- Publication Year :
- 2019
- Publisher :
- eScholarship, University of California, 2019.
-
Abstract
- Laser speckle imaging (LSI) is a wide-field, noninvasive optical technique that allows researchers and clinicians to quantify blood flow in a variety of applications. However, traditional LSI devices are cart or tripod based mounted systems that are bulky and potentially difficult to maneuver in a clinical setting. We previously showed that the use of a handheld LSI device with the use of a fiducial marker (FM) to account for motion artifact is a viable alternative to mounted systems. Here we incorporated a handheld gimbal stabilizer (HGS) to produce a motion stabilized LSI (msLSI) device to further improve the quality of data acquired in handheld configurations. We evaluated the msLSI device in vitro using flow phantom experiments and in vivo using a dorsal window chamber model. For in vitro experiments, we quantified the speckle contrast of the FM (K(FM)) using the mounted data set and tested 80% and 85% of K(FM) as thresholds for useable images (K(FM,Mounted,80%) and K(FM,Mounted,85%)). Handheld data sets using the msLSI device (stabilized handheld) and handheld data sets without the HGS (handheld) were collected. Using K(FM,Mounted,80%) and K(FM,Mounted,85%) as the threshold, the number of images above the threshold for stabilized handheld (38 ± 7 and 10 ± 2) was significantly greater (p = 0.031) than for handheld operation (16 ± 2 and 4 ± 1). We quantified a region of interest within the flow region (K(FLOW)), which led to a percent difference of 8.5% ± 2.9% and 7.8% ± 3.1% between stabilized handheld and handheld configurations at each threshold. For in vivo experiments, we quantified the speckle contrast of the window chamber (K(WC)) using the mounted data set and tested 80% of K(WC) (K(WC,Mounted,80%)). Stabilized handheld operation provided 53 ± 24 images above K(WC,Mounted,80%), while handheld operation provided only 23 ± 13 images. We quantified the speckle flow index (SFI) of the vessels and the background to calculate a signal-to-background ratio (SBR) of the window chamber. Stabilized handheld operation provided a greater SBR (2.32 ± 0.29) compared to handheld operation (1.83 ± 0.21). Both the number of images above threshold and SBR were statistically significantly greater in the stabilized handheld data sets (p = 0.0312). These results display the improved usability of handheld data acquired with an msLSI device.
- Subjects :
- 0303 health sciences
Materials science
ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION
Laser Speckle Imaging
Optical Physics
Materials Engineering
Gimbal
01 natural sciences
Atomic and Molecular Physics, and Optics
Article
010309 optics
Data set
03 medical and health sciences
Speckle pattern
Region of interest
0103 physical sciences
Speckle imaging
Fiducial marker
Mobile device
030304 developmental biology
Biotechnology
Biomedical engineering