Single-centre Prospective Comparison Between Contrast-Enhanced Ultrasound and Computed Tomography Angiography after EVAR
- Source :
- European Journal of Vascular and Endovascular Surgery. 42:797-802
- Publication Year :
- 2011
- Publisher :
- Elsevier BV, 2011.
-
Abstract
- Aim: To evaluate contrast-enhanced ultrasound (CEUS) as an effective alternative to CT-angiography (CTA) for endoleak detection and aneurismal sac diameter measurement in the follow-up after endovascular abdominal aortic aneurysm repair (EVAR). Methods: From January 2006 to December 2010, 395 patients underwent EVAR follow-up with both CTA and CEUS. The diameter of the aneurismal sac and the presence of endoleaks were evaluated in all the 395 paired examinations. Results: Bland-Altman plots showed a good agreement in aneurismal sac diameter evaluation between the two imaging modalities. The mean diameter was 54.93 mm (standard deviation (SD) ±12.57) with CEUS and 56.01 mm (SD ± 13.23) with CTA. The mean difference in aneurismal sac diameter was -1.08 mm ± 3.3543 (95% confidence interval (CI), -0.75 to -1.41), in favour of CTA. The number of observed agreement in endoleak detection was 359/395 (90.89%). The two modalities detected the same type I and type III endoleaks. McNemar's Ï 2 test confirmed that CTA and CEUS are equivalent in endoleak detection. Conclusions: CEUS demonstrated to be as accurate as CTA in endoleak detection and abdominal aortic aneurysm diameter measurements during EVAR follow-up, without carrying the risks of radiation exposure or nephrotoxicity. Even if it cannot be proposed as the sole imaging modality during follow-up, our analysis suggests that it should have a major role. © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
- Subjects :
- medicine.medical_specialty
Endoleak
Iohexol
medicine.medical_treatment
Sulfur Hexafluoride
Contrast Media
Prosthesis Design
Sensitivity and Specificity
Aortography
Endovascular aneurysm repair
Follow-Up Studie
Blood Vessel Prosthesis Implantation
McNemar's test
medicine
Humans
cardiovascular diseases
Ultrasonography, Doppler, Color
Computed tomography
Phospholipids
Computed tomography angiography
Medicine(all)
medicine.diagnostic_test
business.industry
Angioplasty
Ultrasound
medicine.disease
Abdominal aortic aneurysm
Confidence interval
Iopamidol
Phospholipid
Single centre
Ultrasonography, Doppler, Pulsed
Surgery
Radiology
Tomography, X-Ray Computed
Cardiology and Cardiovascular Medicine
business
Contrast-enhanced ultrasound
psychological phenomena and processes
Follow-Up Studies
Aortic Aneurysm, Abdominal
Human
Subjects
Details
- ISSN :
- 10785884
- Volume :
- 42
- Database :
- OpenAIRE
- Journal :
- European Journal of Vascular and Endovascular Surgery
- Accession number :
- edsair.doi.dedup.....5a2609d12ac41339829781c866389346
- Full Text :
- https://doi.org/10.1016/j.ejvs.2011.09.003