Back to Search
Start Over
Impact of different phased-array coils on the quality of prostate magnetic resonance images
- Source :
- European Journal of Radiology Open, European Journal of Radiology Open, Vol 8, Iss, Pp 100327-(2021)
- Publication Year :
- 2021
- Publisher :
- Elsevier, 2021.
-
Abstract
- Highlights • Image quality is similar for different body phased-array receive coil setups. • An 18-channel body phased-array receive coil setup achieved good image quality. • 60-channel body phased-array receive coil setup slightly improves SNR in T2W images.<br />Purpose To evaluate the influence of body phased-array (BPA) receive coil setups on signal-to-noise ratio (SNR) and image quality (IQ) in prostate MRI. Methods This prospective study evaluated axial T2-weighted images (T2W-TSE) and DWI of the prostate in ten healthy volunteers with 18-channel (18CH), 30-channel and 60-channel (60CH) BPA receive coil setups. SNR and ADC values were assessed in the peripheral and transition zones (TZ). Two radiologists rated IQ features. Differences in qualitative and quantitative image features between BPA receive coil setups were compared. After correction for multiple comparisons, p-values
- Subjects :
- Image quality
Phased array
R895-920
BPA, Body phased-array
PSTT, Post-hoc paired-sample t-tests
610 Medicine & health
mpMRI, Multi-parametric magnetic resonance imaging
Article
030218 nuclear medicine & medical imaging
Medical physics. Medical radiology. Nuclear medicine
03 medical and health sciences
ERC, Endorectal coil
ROIs, Region of interests
Magnetic resonance imaging
0302 clinical medicine
ICC, Intra-class correlation coefficient
Prostate
Prostate imaging
Healthy volunteers
2741 Radiology, Nuclear Medicine and Imaging
ANOVA, Analysis of variances
SD, Standard deviation
Medicine
Radiology, Nuclear Medicine and imaging
18CH, BPA 18-channel body array coil
Computer Science::Information Theory
60CH, BPA 60-channel body array coil
SNR, Signal to noise ratio
medicine.diagnostic_test
10042 Clinic for Diagnostic and Interventional Radiology
business.industry
T2W-TSE, T2-weighted turbo spin echo
IQR, Interquartile range
30CH, BPA 30-channel body array coil
medicine.anatomical_structure
Signal-to-noise ratio (imaging)
Electromagnetic coil
030220 oncology & carcinogenesis
ss-DWI-EPI, Single-shot diffusion-weighting spin-echo echo-planar imaging
10046 Balgrist University Hospital, Swiss Spinal Cord Injury Center
Signal-to-noise ratio
business
Nuclear medicine
Endorectal coil
Subjects
Details
- Database :
- OpenAIRE
- Journal :
- European Journal of Radiology Open, European Journal of Radiology Open, Vol 8, Iss, Pp 100327-(2021)
- Accession number :
- edsair.doi.dedup.....5b06cf97c831664d3326d5c4d733aabb
- Full Text :
- https://doi.org/10.5167/uzh-201718