Back to Search Start Over

Intra-rater reliability of rectus abdominis diastasis measurement using dial calipers

Authors :
Sue Jones
Sue Boxer
Source :
Australian Journal of Physiotherapy. 43:109-114
Publication Year :
1997
Publisher :
Elsevier BV, 1997.

Abstract

To date, physiotherapists have relied upon the use of finger widths for measurement of rectus abdominis diastasis (RAD). This method has been proven unreliable, due to variations in finger widths. The intra-rater reliability of dial calipers for measurement of RAD was investigated by this study, using a repeated measures design. Measurements were taken at rest and during contraction on three occasions in 30 postpartum subjects. High reliability was demonstrated for resting and active RAD measurements, (ICC = 0.93 and 0.95 respectively). In conclusion, dial calipers are a reliable measuring device when used by a single clinician. Further testing is required to determine inter-rater reliability.

Details

ISSN :
00049514
Volume :
43
Database :
OpenAIRE
Journal :
Australian Journal of Physiotherapy
Accession number :
edsair.doi.dedup.....5b1fb96215d88855eee33d1806585aec
Full Text :
https://doi.org/10.1016/s0004-9514(14)60405-0